Culligan Gold Series Installation & Operation Instructions page 62

Gold series
Hide thumbs Also See for Gold Series:
Table of Contents

Advertisement

Appendix A
Table 1 - Dimension "X" is the exposed length the Aqua-Sensor
board connector). You can then verify the Aqua-Sensor probe is inserted to the proper depth by confirming dimension "X" is at
the corrected length.
Model
9" Quadra-Hull
Tank
10" Quadra-Hull Tank
12" Quadra-Hull Tank
14" Quadra-Hull Tank
Table 2 - Maximum Allowable Drain Line Length
Operating
0 ft (0m)
Pressure
30psi (210 kPa)
60 ft (18 m)
40 psi (279 kPa)
100 ft (30 m)
50 psi (349 kPa)
145 ft (41 m)
60 psi (419 kPa)
80 psi (559 kPa)
100 psi (669 kPa)
Table 3 - Media Volumes and Freeboard
Model
9"
10"
12"
14"
* Measured from the top of the resin to the top surface of tank threads.
Table 4 - Flow Rates
Model
Service
9"
9.0 gpm @ 13 psi
10"
9.6 gpm @ 15 psi
12"
10.0 gpm @ 15 psi
14"
10.6 gpm @ 16 psi
60
Culligan Gold Series
®
Water Softener
2 ft (0.6m)
50 ft (15 m)
90 ft (27 m)
115 ft (35 m)
Normal Installation should not require
more than 100 ft (30 m) of drain line
Cullex
(ft
) (A)
®
3
1.0
1.5
2.0
3.0
Backwash/Fast Rinse
1.6 - 2.2 gpm
1.6 - 2.2 gpm
2.6 - 4.0 gpm
5.5 - 6.7 gpm
cord (cord length from the Aqua-Sensor plug to the circuit
®
X
34 1/2"
30 1/2"
32 1/2"
22 1/2"
4 ft (1.2m)
6ft (1.8m)
30 ft (9 m)
15 ft (5 m)
70 ft (21 m)
50 ft (15 m )
80 ft (24 m)
80 ft (24 m)
100 ft (30 m)
100 ft (30 m)
140 ft (43 m)
150 ft (46 m)
Cullsan (lbs) (B)
12
15
16
25
Brine Draw
0.44 gpm
0.44 gpm
0.93 gpm
1.85 gpm
Y
40"
44"
42"
52"
8ft (2.4m)
10ft (3m)
Not allowable
Not allowable
30 ft (9 m)
12 ft (4 m)
60 ft (18 m)
40 ft (12 m)
85 ft (26 m)
60 ft (18 m)
120 ft (37 m)
Freeboard (in)* (C)
14.5
14.5
16
20
Slow Rinse
Refill
0.27 gpm
0.45 gpm
0.27 gpm
0.45 gpm
0.27 gpm
0.80 gpm
1.35 gpm
0.80 gpm

Hide quick links: