Display Icons
The display is to be backlit and have the icons as shown below.
Custom LCD Display
Six standard 12-segment alpha-numeric characters, a decimal separating the first and
second character, a colon separating the second and third character positions, AM, PM,
REGEN, EFFICIENCY MODE, TODAY'S, AVG DAILY, WATER USAGE, SOFTWATER,
REMAINING, %, MINS, BACKWASH, BRINE RINSE, FAST RINSE, /, REFILL, GALLONS,
LITERS, FLOW RATE, GPM, LPM Icons
A further description of each programming setting and the corresponding display is outlined below. For a display that has an
icon that is displayed solid for the 2 second time period prior to bringing up the settings, the settings menu can be reached prior
to the two second time out by pressing the "Up" or "Down" key.
Beeper Setting - This setting is used to turn the beeper on or off for each key press
actuation. The display will show "bEEP X" where X is either "Y" or "N". The "Y" or "N"
will be toggled with the "Up" and "Down" keys. Setting the Beep option to "N" will only
disable the beeper for key press actuation. The beeper will still be active for error and
alarm codes.
Pressing the "Program" key will save the setting and move to the next programming
step.
Time of Day - This setting is used to program the current time of day. When in this
step the display will first show "tod" for two seconds.
After "tod" is displayed, "12:00 PM" will display (or the current set time if already
programmed) and the minutes will flash. The minutes are adjusted with the "Up" or
"Down" key until the correct value is displayed.
Press the "Regen" key to flash the hours.
Adjust with the "Up" or "Down" key until the
correct time is displayed.
Pressing the "Program" key will save setting and
move to the next programming step. Pressing
"Regen" will move back to the minutes adjust.
Time of Regeneration - This setting is used to program the time at which a
regeneration is to occur in the delay mode, or in immediate mode with time clock
backup on. The display will first show "tor" for two seconds.
After "tor" is shown the display will then show the default of 2:00 AM (or the current
programmed time of regeneration if already set). The time can be adjusted in 30
minute increments by pressing the "Up" or "Down" keys.
Pressing the "Program" key will save the setting and move to the next programming
step.