Step 9 Finishing - Heat & Glo SL-350TRS-CE-D Installer's Manual

Fireplace
Hide thumbs Also See for SL-350TRS-CE-D:
Table of Contents

Advertisement

CAUTION
OPTIONAL WALL SWITCH
THERMOSTAT OR REMOTE
REMOTE SWITCH
Figure 30. Standing Pilot Ignition Wiring Diagram
Step 9
Finishing
Only non-combustible
materials may be used
to cover the black
fireplace front.
32
!
LABEL ALL WIRES PRIOR T O DISCONNECTION
WHEN SERVICING CONTROLS. WIRING ER-
RORS CAN CAUSE IMPROPER AND DANGER-
OUS OPERATION. VERIFY PROPER OPERA-
TION AFTER SERVICING.
ON/OFF
SWITCH
PIGTAIL
The following diagram shows the minimum vertical
and corresponding maximum horizontal dimensions
of fireplace mantels or other combustible projections
above the top front edge of the fireplace. See Figures
2 , 3 and 4 for other fireplace clearances.
Figure 31.
!
WARNING: DO NOT CONNECT 230 V AC
TO THE WALL SWITCH OR THE
CONTROL VALVE WILL BE DESTROYED.
TP/TH
TP
OFF
TH
ON
THERMOPILE
102
76
50
Minimum Vertical and Maximum
Horizontal Dimensions of Combustibles
above Fireplace
WARNING: WHEN FINISHING THE
FIREPLACE, NEVER OBSTRUCT OR
MODIFY THE AIR INLET/OUTLET
GRILLES IN ANY MANNER.
THERMOCOUPLE
GAS VALVE
o
45
305
254 279
227
203
158
152
127

Advertisement