Tally Setup - junger MIX4 Operation Manual

Small desktop mixer
Table of Contents

Advertisement

For many installations, Tally (GPO) outputs are necessary to remote control external devices or to signal
conditions such as On Air. from HW revision 4 of the base unit, the physical outputs are relay contacts (see
pin assignment and electrical specs).
The MIX4 has 8 Hardware Tally (GPO) outputs - HTally 01 to HTally 08
There are 8 rows in this pane for Hardware Tally setup. HTally 01 is typical of the 8 in the hardware group.
Here will be distinguished whether it will be a static signal NC (normally closed) / NO (normally open)
or if it is a 100ms pulse
Signal Type
Static + / Staic -
Start + / Start -
Stop + / Stop -
For each Tally one of the predefined types can be selected :
Tally Type
OFF
FaderStart
ButtonStart
Event
Hybrid
Button+FaderStart
Finally the triggering source (related to one of the MIX4 inputs) or the triggering event must be selected :
Event
On Air
Talkback
Lim A, B, C, D, Lim All
USERx button
BUSx button
A scratchpad for making notes regarding external connections rounds up this set up area.
Tally (GPO) setup
NC / NO
100ms puls NO / 100ms puls NC
100ms puls NO / 100ms puls NC