Model HR-733

5.0 Installation

5.1 Required Cables

1 or 2 HDMI cables to connect up to 2 HDMI sources to the HR-
733-S
HDMI cable to connect the HR-733-R to the HDMI display
HD-15 male-to-male VGA cable to connect a PC analog video or
an HD-15 to 3-RCA for component YPbPr DVD video
connection to the HR-733-S
3.5mm stereo audio cable or optical (TOSLINK) audio cable to
connect associated audio of VGA/YPbPr source to the sender
RS-232 DB9 male-to-female (pin to pin) cable to connect the
HR-733-S's serial port to a PC
Multi-mode (MM) fiber-optic cable to connect the HR-733-S and
HR-733-R
5.2 Inputs & Outputs
The HR-733-S has 2 HDMI inputs, 1 VGA/YPbPr input with audio, and a
bi-directional RS232 port. The audio source of the VGA/YPbPr input can
be either 3.5mm L/R stereo or optical.
The HR-733-R has l HDMI output and 1 bi-directional RS232 port.

5.3 Fiber Optic Cable Requirements

Each end of the HR-733 uses a single SC connector and requires a multi-
mode fiber-optic cable. Unlike some other fiber-optic equipment that may
work with either single-mode or multi-mode cables,
the HR-733 is not compatible with single-mode
cables. Multi-mode cables are generally available in
OM1, OM2, or OM3 constructions. The OM3
cables are best suited for max transmission lengths
and are recommended for this product.
6
Figure 3
SC Fiber Connector