Finishing; Front Panel Removal And Installation - Fujitsu ASU24CL Installation Manual

Fujitsu split type room air conditioner
Hide thumbs Also See for ASU24CL:
Table of Contents

Advertisement

FINISHING

(1) Insulate between pipes.
● For rear, right, and bottom piping, overlap the connection pipe heat insu-
lation and indoor unit pipe heat insulation and bind them with vinyl tape
so that there is no gap.
● For left and left rear piping, butt the connection pipe heat insulation and
indoor unit pipe heat insulation together and bind them with and vinyl
tape so that there is no gap.
● For left and left rear piping, wrap the area which accommodates the rear
piping housing section with cloth tape.
● For left and left rear piping, bind the connection cord to the top of the
pipe with vinyl tape.
● For left and left rear piping, bundle the piping and drain hose together by
wrapping them with cloth tape over the range within which they fit into
the rear piping housing section.
(2) Temporarily fasten the connection cord along the connection pipe with vinyl
tape. (Wrap to about 1/3 the width of the tape from the bottom of the pipe so
that water does not enter.)
(3) Fasten the connection pipe to the outside wall with saddles, etc.
(4) Fill the gap between the outside wall pipe hole and the pipe with sealer so
that rain water and wind cannot blow in.
(5) Fasten the drain hose to the outside wall, etc.
(Saddle)
Pipe

FRONT PANEL REMOVAL AND INSTALLATION

THE INTAKE GRILLE REMOVAL
(1) Open the intake grille.
(2) Pull down the knob.
(3) Lift the intake grille upward, until the axle at the top of the
intake grille is removed.
THE INTAKE GRILLE INSTALLATION
(1) The fixing axle of the intake grille is installed on the Panel.
(2) Lay down the intake grille.
THE FRONT PANEL REMOVAL
(1) Remove intake grille (Reference the intake grille removal.)
(2) Remove six screws.
(3) The thumb is hung on the lower part as shown in the figure,
and it pulls to the front, pushing [-] mark , and bottom hooks
(two position) is removed from wall hook bracket.
(4) The front panel is pulled to the front, raising the upper sur-
face, and a front panel is removed.
THE FRONT PANEL INSTALLATION
(1) Firstly, fit the lower part of the front panel, and insert top and
bottom hooks. (Three top sides)
(2) Six screws is attached.
(3) The intake grille is attached.
Install the front panel and INTAKE GRILLE securely. If installation is imperfect, the front panel or INTAKE GRILLE
may fall off and cause injury.
(Outside wall cap)
(Sealer putty)
(Outdoors)
Wall
Indoor unit
CAUTION
Connection pipe
(heat insulation)
Bind the pipes together so
that there is no gap.
Pipe
Drain hose
Left piping
Connection cord
Pipe
For connection from the left rear
Wall pipe
Drain hose
Check the following:
Drain hose
GOOD
Saddle
Intake grille
Mounting shaft
Bearing
Front panel
Screws (6 position)
Front panel
Wall hook bracket
Push
[-] mark
Push
Top holes (two sides)
Top hole (center)
Overlap the insulation
Indoor unit pipe
(heat insullation)
Vinyl tape
Wrap with
cloth tape
Cloth tape
Drain hose
Connection cord
Connection pipe
BAD
BAD
BAD
Lifted up
Wave
End in water
Intake grille
Knob
Front panel
Top hook (center)
Front panel
Top hooks
(two sides)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asu24rl

Table of Contents