GENERAL
This INSTALLATION MANUAL briefly outlines where
and how to install the air conditioning system. Please
read over the entire set of instructions for the indoor
and outdoor units and make sure all accessory parts
listed are with the system before beginning.
1. TYPE OF COPPER PIPE AND INSULATION MATERIAL
Copper tubing for connectin the outdoor unit to the indoor
unit and insulation material is available for purchase locally.
When you purchase them, please specify the following.
A. Deoxidized annealed copper pipe for refrigerant piping as:
Small pipe
Outer diameter
Thickness
0.031496 in
1/4"(6.35 mm)
(0.8 mm)
Cut each pipe to the appropriate length +12" (30 cm)
to16" (40 cm) to dampen vibration between units.
B. Foamed polyethylene insulation for copper pipes as
required to precise length of piping. Wall thickness
of the insulation should not be less than 5/16" (8 mm).
C. Use insulated copper wire for field wiring.
CAUTION
Check local electrical codes and regulations
before obtaining wire. Also, check any specified
instructions or limitations.
2. ADDITIONAL MATERIALS REQUIRED FOR INSTALLATION
A. Refrigeration (armored) tape
B. Insulated staples or clamps for connecting wire
(See your local electrical codes.)
C. Putty
D. Refrigeration lubricant
E. Clamps or saddles to secure refrigerant piping

3. OPERATING RANGE

Cooling/Dry Mode
Outdoor temperature
About 14 to 115 °F
Indoor temperature
About 64 to 90 °F
Indoor humidity
About 80% or less

ADDITIONAL CHARGE

Refrigerant suitable for a piping length of 49 ft (15 m) is charged in
the outdoor unit at the factory.
When the piping is longer than 49 ft (15 m), additional charging is necessary.
For the additional amount, see the table below.
66 ft (20 m)
Pipe length
Additional
3.5 oz (100 g)
refrigerant
Between 49 ft (15 m) and 99 ft (30 m), when using a connection pipe
other than that in the table, charge additional refrigerant with 0.21 oz/
ft (20g/1 m) as the criteria.
CAUTION
(1) When adding refrigerant, add the refrigerant from
the charging port at the completion of work.
(2) The maximum length of the piping is 99 ft (30
m). If the units are further apart than this, cor-
rect operation can not be guaranteed.
Large pipe
Outer diameter
Thickness
0.03937 in
5/8"(15.88 mm)
(1.0 mm)
Heating Mode
About 5 to 75 °F
88 °F or less
99 ft (30 m)
83 ft (25 m)
9.0 oz (200 g)
10.5 oz (300 g)

STANDARD ACCESSORIES

The following installation accessories are supplied. Use them as
required.
Name and Shape Q'ty Name and Shape Q'ty
Wall hook bracket
1
Remote
control
unit
Battery
2
Remote control
unit holder
Drain pipe
(Reverse cycle
model only)
The following items are necessary to install this air conditioner. (The
items are not included with the air conditioner and must be purchased
separately.)
Name
Connection pipe assembly
Connection cord
Wall pipe
Decorative tape
Vinyl tape
Wall cap
Saddle
Drain hose
Tapping screws
Sealant

ELECTRICAL REQUIREMENT

Always make the air conditioner power supply a special branch cir-
cuit and provide a special switch and receptacle. Do not extend the
power cord.
MINIMUM CIRCUIT AMPACITY
MAXIMUM OVERCURRENT PROTECTION
(TIME DELAY FUSE OR HACR TYPE CIRCUIT BREAKER)
Cloth tape
Tapping screw (big)
1
Tapping screw (small)
Air cleaning filter
Air cleaning filter frame
1
Insulation (Drain hose)
1
CAUTION
21 A
25 A
1
8
2
2
2
1
Q'ty
1
1
1
1
1
1
1 set
1
1 set
1