Mounting End Plate (PFP-M)
Depending on the installation type, an Amplifier Unit may
move during operation. In this case, use an End Plate.
Before installing an End Plate, remove the clip from the mas-
ter Amplifier Unit using a nipper or similar tool.
The sensor bottom is also equipped with the clip removing
mechanism.
1. Insert the clip to be removed into the slit underneath the clip
on another Amplifier Unit.
Accessories
Use of E39-R3 Reflector
1. When using an adhesive tape on the rear face, apply it after
washing away oil, dust, etc. from the place of application.
The reflector cannot be installed if there remains oil, etc.
2. The E39-R3 cannot be used in places where it is exposed
to oil or chemicals.
E39-F32# Protective Spiral Tubes
1. Insert a fiber to the Protective Spiral Tube from the head
connector side (screwed) of the tube.
Protective
Spiral Tube
2. Push the fiber into the Protective Spiral Tube. The tube
should be straight so that the fiber is not twisted when in-
serted. Then turn the end cap of the spiral tube.
Protective
Spiral Tube
3. Secure the Protective Spiral Tube on a suitable place with
the attached nut.
Mounting panel
Protective
Spiral Tube
E3X-NA
Fiber Unit
Fiber Unit
Hexagon clamping nut
Fiber Unit
Toothed washer
2. Remove the clip by rotating the Amplifier Unit.
Rotate
Pull Strengths for Connectors (Including Cables)
E3X-CN11: 30 N max. E3X-CN12: 12 N max.
4. Use the attached saddle to secure the end cap of the Pro-
tective Spiral Tube. To secure the Protective Spiral Tube at
a position other than the end cap, apply tape to the tube so
that the portion becomes thicker in diameter.
Saddle
Tube
End cap
E39-F10 Fiber Connector
Fit the connector in the following procedure.
A
Splice
Fiber Unit
Retention
Retention unit
unit
Fiber Unit
• The Fiber Units should be as close as possible when they
are connected. Sensing distance will be reduced by approx-
imately 25% when fibers are connected.
• Only 2.2 mm dia. fibers can be connected.
B
Fiber Unit
Fiber Unit
A-89