Fiber Units
Installation
Tightening Force
The tightening force applied to the Fiber Unit should be as fol-
lows:
Screw-mounting
Spring mounting clip
Toothed washers
Nuts
(attachment)
Fiber Units
M3/M4 screw
M6 screw/6 mm dia. column
1.5 mm dia. column
2 mm dia./3 mm dia. column
E32-T12F 5 mm dia. Teflon model
E32-D12F 6 mm dia. Teflon model
E32-T16
E32-R21
E32-M21
E32-L25A
E32-T16P
E32-T16PR
E32-T24S
E32-L24L
E32-L25L
E32-T16J
E32-T16JR
E32-T16W
E32-T16WR
Use a proper-sized wrench.
Fiber Connection and Disconnection
The E3X Amplifier Unit has a lock button. Connect or discon-
nect the fibers to or from the E3X Amplifier Unit using the fol-
lowing procedures:
1. Connection
Open the protective cover, insert the fibers according to the fi-
ber insertion marks on the side of the Amplifier Unit, and lower
the lock button.
Lock Button
Fiber insertion mark
Fiber
E3X-NA
Model Cylindrical Model
Retaining screw
(flat head or
sunken head)
Clamping torque
0.78 Nm max.
0.98 Nm max.
0.2 Nm max.
0.29 Nm max.
0.78 Nm max.
0.49 Nm max.
0.59 Nm max.
0.49 Nm max. for up to 5 mm from
front end, 0.78 Nm max. for more
than 5 mm from front end
0.78 Nm max.
0.29 Nm max.
0.3 Nm max.
Insertion position
10.7mm
2. Disconnection
Remove the protective cover and raise the lock button to pull
out the fiber.
Unlocked
Locked
Note:To maintain the fiber properties, confirm that the lock is
released before removing the fiber.
3. Precautions for Fiber Connection/Disconnection
Be sure to lock or unlock the lock button within an ambient
temperature range between -10°C and 40°C.
Cutting Fiber
• Insert a fiber into the Fiber Cutter and determine the length
of the fiber to be cut.
• Press down the Fiber Cutter in a single stroke to cut the fi-
ber.
• The cutting holes cannot be used twice. If the same hole is
used twice, the cutting face of the fiber will be rough and the
sensing distance will be reduced. Always use an unused
hole.
• Cut a thin fiber as follows:
An attachment is
temporarily fitted
A
to a thin fiber be-
fore shipment.
Secure the attach-
ment after adjust-
ing the position of
B
it in the direction
indicated by the
arrow.
Insert the fiber to
C
be cut into the
E39-F4.
Three holes
for standard
fiber (2.2-mm dia.)
Finished state
D
(proper cutting
state)
Note: Insert the fiber in the direction indicated by
the arrow.
Protective cover
Thin fiber
attachment
(E39-F9)
Temporarily
fitted
E39-F4
fiber cutter
Two holes for thin fiber
Approx. 0.5 mm
Insertion direction
A-87