4.0 Manual Run

The first option available in the controller menu is MANUAL RUN.
MANUAL RUN is useful for checking the proper operation of stations
(especially after installation), for applying a temporary program for a defined
time period and for repeat testing of a selected valve using MANUAL TEST.
To shut off all controllers in range with the same CLIENT ID for a specified
number of days use GLOBAL STOP.
MANUAL RUN has priority over a program and will suspend a program or
valve watering schedule.
Note that at the completion of MANUAL RUN, any programmed irrigation
schedule reverts back to normal operation.
Press
and navigate to MANUAL RUN icon. Press
RUN MENU screen. Use the same procedures to select other icons as needed.
a. Manual Test
Manual Test operates each valve by turning the first valve on and off as many
times as desired, then repeats for the second valve, if needed.
In the CONTROLLER MENU screen press
Press
, MANUAL RUN MENU screen appears. Press
MANUAL TEST icon.
Press
to connect. (If the controller is active, a screen will display program
is running. In order to use manual test, the running program must be
suspended). If the program is suspended, CONNECTING appears briefly, then
CONNECTED and then, the MANUAL TEST screen with the valve number,
the words TURN ON blinking and SKIP TO NEXT appears. Press
on valve #1, CONNECTING appears briefly, then CONNECTED, then UPDATE
SUCCESSFUL and then Valve #1 with TURN ON blinking. To turn off Valve #1
press
. After turning Valve #1 off, repeat the steps to turn valve #1 ON or
use SKIP TO NEXT, to skip to Valve #2 and then to exit. Repeat the steps for
each valve as needed. If the valve is not turned off via the handset, it will turn
off automatically after 3 minutes.
to enter MANUAL
and highlight MANUAL RUN icon.
and highlight
to turn
18
CONTROLLER MENU
10:00
10:00
10:00
UPLOADING
MANUAL RUN
MANUAL TEST
CONNECT
10:00
10:00
10:00
ARE YOU SURE?
CONNECTING
CONNECTED
YES/NO
CONNECT
CONNECT
10:00
10:00
10:00
b. Manual Temp
UPLOADING
Manual Temp is useful for applying additional water for a defined irrigation
period.
MANUAL RUN
MANUAL TEMP
CONNECT
In the CONTROLLER MENU screen press
10:00
10:00
10:00
Press
and MANUAL RUN MENU screen appears. Press
ARE YOU SURE?
DOWNLOADING
CONNECTED
highlight MANUAL TEMP icon.
Press
to connect. (If the controller is active, a screen will display Program
Running or Manual Run Active. In order to use Manual Temp, the running
YES/NO
CONNECT
CONNECT
program must be suspended by pressing
10:00
10:00
suspended CONNECTING appears briefly, then CONNECTED and then the
MANUAL TEMP screen with the valve number, the hour digits blinking within
valve # 1 appears. To set a defined irrigation period press
the hour digits, then press
and set the minute digits. Repeat the steps for
MANUAL RUN
EXIT
Valve #2. Press
to connect, ARE YOU SURE? screen appears. Press
again to initiate a temporary program. When finished select the EXIT icon by
pressing
or
. Press
to exit.
10:00
10:00
CONNECTED
TURN ON
SKIP TO NEXT
MANUAL TEST
CONNECT
10:00
10:00
UPDATE
SUCCESSFUL
TURN OFF
SKIP TO NEXT
CONNECT
MANUAL TEST
10:00
10:00
CONNECTED
00:00
00:00
MANUAL TEMP
CONNECT
and highlight MANUAL RUN icon.
10:00
then
and
UPDATE
SUCCESSFUL
CONNECT
again.) If the program is
or
and set
19