RIKA INTEGRA II Manual page 23

Freestanding wood pellet stove
Hide thumbs Also See for INTEGRA II:
Table of Contents

Advertisement

PROGRAMMING THE CONTROL
If you intend to operate your stove manually, set it to
the manual mode by pressing the ENTER button
until the display no longer reads either "SB" or "TM".
During start-up, the stove will read "ST" on the first
display line, and "21" on the second display line.
"ST" stands for start-up and "21" is the remaining
start-up time in minutes (the time display will
decrease as the start-up progresses).
During the start-up cycle, only the auger and
combustion fan operate with the combustion fan
gradually increasing in speed. The convection fan
will turn on at the end of the start-up cycle.
NOTE: As long as the stove is running, whether in
the start-up mode, cleaning cycle, in normal
operation, or while operating under the timed mode,
you can increase or decrease the heat output level
at any time by pressing the
"+" or "–" keys.
If the stove needs to be turned off at any time, push
the ON/OFF button and the stove will immediately
begin the shut-down process. Complete shut-down
takes a total of eight minutes.
The stove may
remain hot for several hours after turning off.
If the stove is running in timed mode when the
power button is pushed, the schedule will resume at
the next programmed interval.