INSTALLATION
This stove should be installed by an authorized
service technician.
Before installing, contact your local building or fire
officials
about
inspection
requirements
Manufacturer and distributor have no control over
the installation of the stove and assume no
responsibility
for
consequential damages caused by improper
installation.
The following installation guidelines must be
followed to ensure conformity with both the safety
of this stove and with local building codes.
FLOOR PROTECTION
The stove must be installed on a non-combustible
surface. A single-layer 3/8" non-combustible floor
area, or equivalent is required.
EXHAUST SYSTEM DESIGN GUIDELINES
The stove must be connected to an approved
three or four inch pellet vent chimney.
Installation Instructions for more information.
DO NOT INSTALL A FLUE DAMPER IN THE
EXHAUST VENTING OF THIS STOVE!
DO NOT CONNECT THIS STOVE TO A
CHIMNEY
FLUE
APPLIANCE!
The exit terminal must be located no less than 48
inches
from
any
combustion products could enter the building (i.e.
windows and doors), no less than 24 inches from
an adjacent building, and no less than seven feet
above grade, when located adjacent to public
walkways. It must be arranged so that exiting flue
gasses will not be a hazard to people, overheat
combustible structures, or enter into any building.
Copyright © 2008 by Lucky Distributing
restrictions
and
installation
in
your
any
special,
incidental
SERVING
ANOTHER
opening
through
DO
NOT
DISTRIBUTION DUCT OR SYSTEM!
Keep brush, plants, and shrubs at least 36" away
from the vent termination.
area.
The total length of horizontal vent must not exceed
five feet. The "PL" vent exhaust system must be
installed and sealed with three screws per joint.
or
The
chimney
procedures must be followed.
connections, joints, and all pipe seams within the
home should be sealed with high-temperature
silicone sealer, and (RTV) aluminum tape.
ELECTRICAL CONNECTION
The stove is supplied with a 7' to 8' power cord.
This cord must be connected to a properly
polarized, normal 110v, 60Hz grounded electrical
outlet.
approximately 100 watts under normal operation.
During the ignition process (duration of 12
minutes), power consumption is approximately
300 watts. The power cord must be run so that
any contact with hot or sharp-edged external
surfaces is avoided.
COMBUSTION AIR
The combustion process requires oxygen. As a
rule, the combustion air is taken from the living
area in the home. The air taken from the living
area must be re-introduced. Tight fitting windows
and doors could result in insufficient air flow into
See
the house for proper combustion. This situation
becomes more problematic due to additional
ventilation in the house such as kitchen or
bathroom exhaust fans. An additional outside air
source may be necessary for adequate air and
optimum combustion.
VENT CLEARANCES
Install all vent at clearances specified by the vent
manufacturer.
which
CANADIAN INSTALLATION
Where passage through a wall, or partition of
combustible construction is desired, the install
shall conform to CAN/CSA-B365.
Clearances may only be reduced by means of
approved regulatory authority.
13
CONNECT
TO
manufacturer's
The average power consumption is
ANY
AIR
installation
In addition, pipe
1