RIO
Instruction Manual
- 1 -

Advertisement

Table of Contents
loading

Summary of Contents for RIKA Rio

  • Page 1 Instruction Manual - 1 -...
  • Page 2 - 2 -...
  • Page 3 - 3 -...
  • Page 4 - 4 -...
  • Page 5 - 5 -...
  • Page 6: Table Of Contents

    CONTENTS Technical specification and spare parts overview IMPORTANT INFORMATION WHAT ARE PELLETS? Quality characteristics, storage TECHNOLOGY AUTOMATIC SAFETY FUNCTIONS Power failure Overheating Low temperature switch off Electrical excess current switch off INSTALLING THE STOVE General information Making the chimney connection Method Floor protection Safety distances...
  • Page 7 10. CLEANING AND MAINTENANCE Basic Information Cleaning the fire tray Cleaning the grate door glass Cleaning the flue gas channels Cleaning exhaust gas collector Cleaning exhaust gas fan housing Cleaning pellet container Inspecting door seal Checking chimney connection Cleaning air sensor 11.
  • Page 8: Technical Specification And Spare Parts Overview

    TECHNICAL SPECIFICATION SPARE PARTS - OVE RVIEW (Fig. 1) (Fig. 3 - Fig. 7) DESCRIPTION TECHNICAL DATA 01 Fire door Height 1030 02 Fire door seal Width [mm] 03 Fire door glass Depth of the corpus [mm] 04 Upper temperature limiter Weight without casing [daN] 05 Ignition element...
  • Page 9: Important Information

    1. IMPORTANT INFORMATION ● Make children aware of the danger and keep GENERAL WARNING AND SAFETY them away from the stove when in use. INSTRUCTIONS ● Placing non heat resistant objects on the stove or The general introductory warning information must nearby is prohibited.
  • Page 10: Technology

    3. TECHNOLOGY Your new pellet stove is technologically advanced Your operating outlay is reduced to the most as a result of years of tests in the laboratory and in necessary - this prevents operating faults whilst practice. The practical advantages of your pellet working in an optimum fashion at the same time.
  • Page 11: Installing The Stove

    5. INSTALLING THE STOVE chimney, if possible use a connection piece with GENERAL INFORMATION cleaning opening. The stove must be connected to a chimney that is For optimum efficiency please use the type of approved for solid fuels. The chimney must have a connector we recommend.
  • Page 12: Electrical Connection

    Feed of external combustion air ELECTRICAL CONNECTION ● Steel, HT or flexible aluminium pipes must be The stove is supplied with an approx. 2.5 m long used. connecting cable with a plug. The cable must be ● Minimum diameter 5 cm/2 inches. connected to a 230 V, 50 Hz electrical supply.
  • Page 13: General

    6. ASSEMBLY, PANELLING, OPTIONS GENERAL ASSEMBLY OF CONVECTION FAN (OPTIONAL) CAUTION: Only work on the stove when the mains (Fig. 6) plug has been removed from the socket. Dismantle the rear side panels (Fig 6, 45.51) left During assembly do not drop any items (screws) etc. and right by removing the hexagonal screws in the into the fuel container - they can block the conveyor pellet container and at the back in the rear panel.
  • Page 14: Operation

    7. OPERATION BASIC INFORMATION INTERNAL CONTROL UNIT All settings and functions can be regulated The stove must only be started when fully fitted. via this unit. Your pellet stove is exclusively for burning pellets made from wood of a controlled quality. Non-pelletised solid fuels (straw, maize, chopped matter etc.) are not permitted.
  • Page 15: General

    8. DEVICE COMMISSIONING / CONTROL PROGR AMMING / CONTROLOTIONS Now press “ENTER” and the display shows: GENERAL ● Check that the pellet container is full and the combustion chamber is clean and contamination “S1” = start first heating time, 6 the free.
  • Page 16 On selecting the “MENU” key the display shows the If you want to maintain a specific heating output (low following weekday: operation) between the programmed heating times you can set the required value by pressing the “+” or “-” keys. “TU”...
  • Page 17 By pressing the “+” or “-” keys the current hour of Select the desired value by pressing the “+” or “-” the internal clock can be set. The desired value is keys and confirm with “ENTER”. The display then confirmed with “ENTER” and is then saved. The shows: display shows “PN2”...
  • Page 18: Main Menu Operating Areas

    Ensure that when the stove is in ON mode the heating Start manual operation. operation starts after 10 seconds. In automatic mode (TM) the heating process starts in accordance with the The following flashing indicators appear alternately programmed heating times. on the display MAIN MENU...
  • Page 19: Shut Down Unit

    Start automatic operation (TM mode) PLACE STOVE OUT OF OPERATION When TM is selected on the display and the Switching off from “Manual operation” (ON) programmed heating time begins the control starts the heating operation. If the “ON/OFF” key is pressed during operation then the switch off program is activated.
  • Page 20: Shut Down Unit From Automatic Operation

    On completion of the switch off program the display SWITCHING OFF BY CHANGING goes off. When the “ON/OFF key is pressed a re- OPERATINGMODE IN STANDBY start follows. If you change to the Standby mode by pressing the “ENTER” key in “Manual operation” and in automatic operation, then switching off as described in the SWITCHING STOVE...
  • Page 21: Electrical Ignition

    9. ELECTRIC IGNITION The pellet furnace is fitted with an electric ignition. 30 kg of pellets should be sufficient for 16 hours of operation at a setting of “100%”, and about 58 hours This starts to function together with the stove start at a setting of “0%”...
  • Page 22: Cleaning And Maintenance

    10. CLEANING AND MAINTENANCE BASIC INFORMATION If the stove is heated in continuous operation, then it must be switched off twice within 24 hours in order to clean the pan. (danger of flash Your stove must be switched off and have cooled back) down before carrying out any maintenance activities.
  • Page 23: Cleaning Exhaust Gas Collector

    ● Refit the parts you removed in the ,reverse ● Clean the inserted intermediate floor (Fig. order. 5, Part 33) (e.g. with vacuum cleaner) and then remove from combustion chamber ● Now vacuum the combustion residue from the manifold channel. ●...
  • Page 24: Cleaning Exhaust Gas Fan Housing

    INSPECTING THE DOOR SEAL The state of the seals on the doors and glass should be checked at least once per year. Repair or replace the seal dependent on the state. CHECKING CHIMNEY CONNECTION Inspect and clean the connection. The collected flue dust can have a negative effect on the stove performance and represent a safety risk.
  • Page 25: Faults - Causes - Solutions

    11. FAULTS - CAUSES - SOLUTIONS ● See “Routine maintenance” PROBLEM ● Only use a pellet quality recommended by us The fire is burning with a weak, orangecoloured ● Have your specialist dealer set the fuel flame. Pellets are building up in the fire pan, regulating device window is covered in soot.
  • Page 26 CAUTION: checks must only be carried out on the control and cabling when no power is applied to the PROBLEM stove. Only trained personnel may carry out repairs. Fan not running, CAUSE(S): ● Stove has no power supply. CONTROL OF ERROR MESSAGES POSSIBLE SOLUTIONS: If the stove does not stop according to the program ●...
  • Page 27: Appendix

    12. APPENDIX MENU NAVIGATION FOR PROGRAMMING OF THE INTERNAL CONTROL Fig 2: Menu navigation internal control - 27 -...
  • Page 28: Menu Navigation For Programming Of Internal Control

    Stichwort/ Abkürzung Name Beschreibung Operating readiness mode (device Standby-Modus switched off, but active for operation by Tele-Control) On-Modus Manual operation Time-Modus Automatic operation MO, TU, WE, TH, FR, SA, SU Weekdays Monday to Sunday Start 1, Start 2, Heating start times, heating end S1, S2, E1, E2 End 1, End 2 times for automatic operation (TM)
  • Page 29: Keyword, Abbreviation Index

    13. EC DECLARATION OF CONFORMITY - 29 -...
  • Page 30 This is your dealer or your installer. Without correct commissioning, as well as correct instigation according to service manual and the addition for this leaflet, the guarantee claims could not be accepted. Installation certificate for Rika pellet air heating device Date:__________________ Installation address...
  • Page 31: Commission Ing Instructions And Certificate

    For the purpose of timely damage limitation, the deflector plates, combustion chamber liners (e.g. warranty claim on the part of the claimant is to be fireclay), ceramics, natural stone, ignition elements, enforced at the RIKA dealer in writing using the sensors, combustion chamber...
  • Page 32 G U A R A N T E E / G A R A N T I E Purchase day/Date d’achat: Trader stamp/Cachet du revendeur: Model designation/Nom du modéle: Numbers of the vehicle identification plate on the furnace back: Numméros de la plaque signalétique á l’arriére du poêle: Attached by/Raccordé...
  • Page 33 G U A R A N T E E / G A R A N T I E Stamp Customer/Client: Marque To/A:...