If changing from natural gas 20 mbar/13
mbar to liquid gas, completely tighten
the adjustment screw in, until a small
regular flame is obtained.
If changing from liquid gas to natural gas
20 mbar, undo the by-pass screw about
1/2 of a turn, until a small regular flame
is obtained.
If changing from natural gas 20 mbar to
natural gas 13 mbar undo the by-pass
screw about 1/4 of a turn, until a small
regular flame is obtained.
If changing from liquid gas to natural gas
13 mbar, undo the by-pass screw about
3/4 of a turn, until a small regular flame
is obtained.
Reassemble the parts following the same
procedure backwards.
Finally, check the flame does not go out
when quickly turning the knob from the max-
imum position to the minimum position.
Electrical connection
The unit is preset to work with a voltage of
single phase 230 V.
Before making the connection make sure
that:
• the energy power available in the user's
house is sufficient for the normal supply of
this appliance (see rating plate)
• the unit is correctly connected to earth
through a suitable plug and according to
the installation country Laws
• the socket or the omnipolar switch used
for the connection must be easilv reached
with the installed appliance
The appliance is supplied with electric cable,
therefore you will have to fit it with a standard
plug, suitable for the total electric load shown
on the rating plate. The plug is to be inserted
into a suitable wall socket.
If you wish to directly connect to the mains,
you have to interpose an omnipolar switch
with a minimum opening between contacts
of 3 mm, between the unit and the mains,
complying with the existing regulations.
The brown live wire (originating from the
clamp of the appliance junction box) must al-
ways be connected to the phase of the mains
supply. In any case, the supply cord must be
positioned in such a way as it does not reach
in any point a temperature higher by 50
than the room temperature.
Replacement of the electric cable
Warning! The replacement of electric
cable must be carried out exclusively by
the service force centre or by personnel
with similar competencies, in
accordance with the current regulations.
Should the supply cord need to be replaced,
use only the following cable types: H07 RN-
F, H05 RN-F, H05 RRF, H05 VV-F, H05
V2V2-F (T90), H05 BB-F. It is necessary that
the yellow/ green earth wire is about 2 cm
longer than the live and neutral ones (see di-
agram).
The section of the cable should be 3 x 1,5
2
mm
minimum.
After the connection, test the heating ele-
ments for about 3 minutes to ensure that they
are working correctly.
Important! The manufacturer refuses any
responsibility in cases where normal safety
measures are not observed.
1
Phase
2
Ground (yellow - green)
3
Neutral wire
Service and spare parts
If your appliance does not work correctly,
even after carrying out all the checks which
are listed in the previous chapter, then please
contact your local Service Centre, specifying
the type of malfunctioning, the appliance
electrolux 23
°