List of Parameters
Param-
Regis-
Name
eter
ter No.
No.
(Hex)
n176
01B0
Parameter
(See
copy and
note.)
verify func-
tion selection
n177
01B1
Parameter
(See
read prohibit
note.)
selection
n178
01B2
Fault log
n179
01B3
Software
number
Note Parameters for register numbers 01B0 and 01B1 cannot be written from RS–422/485 communications or
the Option Unit. These parameters are read–only.
Description
Selects the function to read, copy,
and verify the parameter between
the memory of the Inverter and that
of the Digital Operator.
rdy: Ready to accept the next com-
mand.
rEd: Reads the Inverter parameter.
Cpy: Copies the parameter to the
Inverter.
vFy: Verifies the Inverter parameter.
vA: Checks the Inverter capacity
display.
Sno: Checks the software number.
Select the copy-prohibit function.
Set this parameter to store the data
in the EEPROM of the Digital Oper-
ator.
0: Read prohibited for Inverter
parameters (data cannot be
stored in EEPROM).
1: Read possible for Inverter param-
eters (data can be stored in
EEPROM).
Used to display the four most recent
fault recorded.
Fault
generation
item
Note The most recent fault is indi-
cated by "1."
Note This parameter is monitored
only.
Used to display the software num-
ber of the Inverter for OMRON's
control reference use.
Note This parameter is monitored
only.
Set-
Default
ting
setting
range
rdy to
rdy
Sno
0, 1
0
---
---
Display
---
---
Chapter 3
Chan-
Memo
ges
during
opera-
tion
No
No
---
---
3-39