Model FDCVA302HENR
SW4
Lower pressure
sensor
(PSL)
Electronic
expansion valve
(EEVC,EEVH)
Function of DIP switch (SW3, 5, 7, 8)
±
Switch
Defrost setting select for Cold regions
ON
SW3-1
Defrost setting select for Normal
OFF
ON
Snow-guard fan control Effective
SW3-2
Snow-guard fan control Invalid
OFF
ON
Defrost prohibited period 37 min.
SW3-4
Defrost prohibited period 45 min.
OFF
Test run operation
ON
SW5-3
OFF
Normal
Test run operation Heating
ON
SW5-4
OFF
Test run operation Cooling
External PCB
SW8
1
Thermistor
(Tho-R1,Tho-D,Tho-S,Tho-A)
CNTH
SW4
CNPS
CNEEV1
CNEEV2
CNFAN
Fan motor
Solenoid valve
(SV1)
4way valve
Function
SW5
SW9
Pump down switch
SW9
SW8
SW5
2
3
1
2
3
4
CNN
CNS
CNR
CNH
Crank case heater
Switch
SW7-1
SW7-2
SW8-2
SW8-3
SW7
SW3
SW7
SW3
1
2
3
1
2
3
261
-
-
CNW
High pressure switch
(63H1)
Function
Changes the fan control at installation of wind direction duct.
ON
Normal
OFF
ON
Anti-defrost : Enabled
Anti-defrost : Disabled
OFF
ON
Cancels compressor dilution protection timer.
Normal
OFF
Cancels compressor starter III.
ON
OFF
Normal
4
Thermistor
(Tho-IP)