Mitsubishi Heavy Industries FDTCVA402HESP2R Technical Manual

Hide thumbs Also See for FDTCVA402HESP2R:

Advertisement

TECHNICAL MANUAL
Collection data
PACKAGED AIR-CONDITIONER
(Spilit system, Air to air heat pump type)
CEILING RECESSED COMPACT TYPE
FDTCVA402HESP2R
CEILING RECESSED TYPE
FDTVA402HES2R
502HES2R
602HES2R
WALL MOUNTED TYPE
FDKNVA402HESP2R
502HESP2R
FDKNVA602HEST2R
MULTI-TYPE (V-MULTI)
PACKAGED AIR-CONDITIONER
(OUTDOOR UNIT)
FDCVA402HESAR
502HESAR
602HESAR
FDTCVA602HEST2R
FDTVA402HESP2R
502HESP2R
602HESP2R
FDTVA602HEST2R
(INDOOR UNIT)
FDTCA201R FDTA201R
Manual No. '07
CEILING SUSPENDED TYPE
FDENVA402HES2R
502HES2R
602HES2R
SATELLITE DUCTED TYPE
FDUMVA402HES2R
502HES2R
602HES2R
FDEN201R
FDKNA201R
251R
251R
301R
301R
DRAFT
PAC-T-115D
FDENVA402HESP2R
502HESP2R
602HESP2R
FDENVA602HEST2R
FDUMVA402HESP2R
502HESP2R
602HESP2R
FDUMVA602HEST2R
FDUMA202R
251R
252R
302R

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Heavy Industries FDTCVA402HESP2R

  • Page 1 DRAFT Manual No. '07 PAC-T-115D • TECHNICAL MANUAL Collection data PACKAGED AIR-CONDITIONER (Spilit system, Air to air heat pump type) CEILING RECESSED COMPACT TYPE CEILING SUSPENDED TYPE FDTCVA402HESP2R FDTCVA602HEST2R FDENVA402HES2R FDENVA402HESP2R 502HES2R 502HESP2R 602HES2R 602HESP2R FDENVA602HEST2R CEILING RECESSED TYPE SATELLITE DUCTED TYPE...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. PACKAGED AIR-CONDITIONER ................ 2. MULTI-TYPE (V MULTI) PACKAGED AIR-CONDITIONER ......2. MULTI-TYPE (V MULTI) PACKAGED AIR-CONDITIONER CONTENTS 1.1 GENERAL INFORMATION................2 1.1.1 Specific features ..................2 1.1.2 How to read the model name ............... 2 1.2 SELECTION DATA ................... 3 1.2.1 Specifications ....................
  • Page 3: Specific Features

    GENERAL INFORMATION 1.1.1 Specific features (1) A new refrigerant, R410A, which causes no damage to the earth’s ozone layer, is used. R410A is a pseudoazeotropic refrigerant, so there is little formation of separate vapor and liquid layers, and it is possible to add refrigerant on-site. (2) Less refrigerant charge amount due to use of double phase refrigerant flow system.
  • Page 4: Selection Data

    SELECTION DATA 1.2.1 Specifications (1) Ceiling recessed compact type (FDTC) (a) Twin type Model FDTCVA402HESP2R (Indoor unit: 2 units, Outdoor unit: 1 unit) FDTCVA402HESP2R Model Item FDTCA201R FDCVA402HESAR Nominal cooling capacity 10.0 [6.1~11.2] Nominal heating capacity 11.2 [5.6~12.5] Power source...
  • Page 5 (b) Triple type Model FDTCVA602HEST2R (Indoor unit: 3 units, Outdoor unit: 1 unit) FDTCVA602HEST2R Model Item FDTCA201R FDCVA602HESAR Nominal cooling capacity 14.0 [6.7~14.8] Nominal heating capacity 16.0 [6.3~16.8] Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 4.64/4.64 Running current (Cooling) 6.8/7.1 98/99 Power factor (Cooling)
  • Page 6: Ceiling Recessed Type (Fdt)

    (2) Ceiling recessed type (FDT) (a) Single type Model FDTVA402HES2R FDTVA402HES2R Model Item FDTA401R FDCVA402HESAR Nominal cooling capacity 10.0 [6.1~11.2] Nominal heating capacity 11.2 [5.6~12.5] Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 2.97 Running current (Cooling) Power factor (Cooling) Heating power consumption 2.92 Running current (Heating)
  • Page 7 Model FDTAV502HES2R FDTVA502HES2R Model Item FDTA501R FDCVA502HESAR Nominal cooling capacity 12.5 [6.5~14.0] Nominal heating capacity 14.0 [6.2~16.0] Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 4.05/4.05 Running current (Cooling) 5.9/6.3 99/98 Power factor (Cooling) 3.97/3.97 Heating power consumption Running current (Heating) 5.8/6.3 99/96...
  • Page 8 Model FDTVA602HES2R FDTVA601HES2R Model Item FDTA601R FDCVA602HESAR Nominal cooling capacity 14.0 [6.7~14.5] Nominal heating capacity 16.0 [6.3~16.5] Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 4.65/4.65 Running current (Cooling) 6.8/7.3 99/97 Power factor (Cooling) 4.54/4.54 Heating power consumption Running current (Heating) 6.7/7.4 98/93...
  • Page 9 (b) Twin type Model FDTVA402HESP2R (Indoor unit: 2 units, Outdoor unit: 1 unit) FDTVA402HESP2R Model Item FDTA201R FDCVA402HESAR Nominal cooling capacity 10.0 [6.1~11.2] Nominal heating capacity 11.2 [5.6~12.5] Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 2.90/2.96 2.94/2.96 Running current (Cooling) 5.1/5.5 4.3/4.6...
  • Page 10 Model FDTVA502HESP2R (Indoor unit: 2 units, Outdoor unit: 1 unit) FDTVA502HESP2R Model Item FDTA251R FDCVA502HESAR 12.5 [6.5~14.0] Nominal cooling capacity 14.0 [6.2~16.0] Nominal heating capacity Power source 3 Phase, 380-415V 50Hz/380V 60Hz 4.29/4.31 Cooling power consumption 2.90/2.96 6.3/6.7 Running current (Cooling) 5.15.5 98/98 Power factor (Cooling)
  • Page 11 Model FDTVA602HESP2R (Indoor unit: 2 units, Outdoor unit: 1 unit) FDTVA602HESP2R Model Item FDTA301R FDCVA602HESAR Nominal cooling capacity 14.0 [7.0~14.5] Nominal heating capacity 16.0 [6.3~16.5] Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 4.69/4.71 Running current (Cooling) 6.9/7.2 98/99 Power factor (Cooling) 4.58/4.60...
  • Page 12 (c) Triple type Model FDTVA602HEST2R (Indoor unit: 3 units, Outdoor unit: 1 unit) FDTVA602HEST2R Model Item FDTA201R FDCVA602HESAR Nominal cooling capacity 14.0 [7.0~14.5] Nominal heating capacity 16.0 [6.3~16.5] Power source 3 Phase, 380-415V 50Hz/380V 60Hz 4.74/4.77 Cooling power consumption 2.90/2.96 6.9/7.4 Running current (Cooling) 5.1/5.5...
  • Page 13: Ceiling Suspended Type (Fden)

    (3) Ceiling suspended type (FDEN) (a) Single type Model FDENVA402HES2R FDENVA402HES2R Model Item FDENA401R FDCVA402HESAR Nominal cooling capacity 10.0 [6.1~11.2] Nominal heating capacity 11.2 [5.9~12.5] Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 2.85/2.85 4.2/4.4 Running current (Cooling) Power factor (Cooling) 98/98 Heating power consumption...
  • Page 14 Model FDENVA502HES2R FDENVA502HES2R Model Item FDENA501R FDCVA502HESAR Nominal cooling capacity 12.5 [6.5~14.0] Nominal heating capacity 14.0 [6.2~16.0] Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 4.35/4.35 Running current (Cooling) 6.4/6.7 98/99 Power factor (Cooling) 3.95/3.95 Heating power consumption Running current (Heating) 5.8/6.1 98/98...
  • Page 15 Model FDENVA602HES2R FDENVA602HES2R Model Item FDENA601R FDCVA602HESRR Nominal cooling capacity 14.0 [6.7~14.5] Nominal heating capacity 16.0 [6.3~16.5] Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 4.95/4.95 7.2/7.6 Running current (Cooling) Power factor (Cooling) 99/99 Heating power consumption 4.69/4.69 Running current (Heating) 6.8/7.2 Power factor (Heating)
  • Page 16 (b) Twin type Model FDENVA402HESP2R (Indoor unit: 2 units, Outdoor unit: 1 unit) FDENVA402HESP2R Model Item FDENA201R FDCVA402HESAR 10.0 [6.1~11.2] Nominal cooling capacity 11.2 [5.9~12.5] Nominal heating capacity Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 2.78/2.78 Running current (Cooling) 4.1/4.3 Power factor (Cooling) 98/98...
  • Page 17 Model FDENVA502HESP2R (Indoor unit: 2 units, Outdoor unit: 1 unit) FDENVA502HESP2R Model Item FDENA251R FDCVA502HESAR 12.5 [6.5~14.0] Nominal cooling capacity 14.0 [6.2~16.0] Nominal heating capacity Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 4.23/4.23 Running current (Cooling) 6.2/6.5 Power factor (Cooling) 98/99 Heating power consumption...
  • Page 18 Model FDENVA602HESP2R (Indoor unit: 2 units, Outdoor unit: 1 unit) FDENVA602HESP2R-P1RSB Model Item FDENA301R FDCVA602HESAR Nominal cooling capacity 14.0 [6.7~14.5] Nominal heating capacity 16.0 [6.3~16.5] Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 4.84/4.84 Running current (Cooling) 7.1/7.4 98/99 Power factor (Cooling) 4.59/4.59...
  • Page 19 (c) Triple type Model FDENVA602HEST2R (Indoor unit: 3 units, Outdoor unit: 1 unit) FDENVA602HEST2R Model Item FDENA201R FDCVA602HESAR 14.0 [6.7~14.5] Nominal cooling capacity 16.0 [6.3~16.5] Nominal heating capacity Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 4.85/4.85 Running current (Cooling) 7.1/7.5 Power factor (Cooling) 99/98...
  • Page 20: Satellite Ducted Type (Fdum)

    (4) Satellite ducted type (FDUM) (a) Single type Model FDUMVA402HES2R FDUMVA402HES2R Model Item FDUMA402R FDCVA402HESAR Nominal cooling capacity 10.0 [6.1~11.2] Nominal heating capacity 11.2 [6.0~12.5] Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 2.80/2.80 Running current (Cooling) 4.2/4.4 Power factor (Cooling) 96/97 2.77/2.80...
  • Page 21 Model FDUMVA502HES2R FDUMVA502HES2R Model Item FDUMA502SR FDCVA502HESAR Nominal cooling capacity 12.5 [6.7~14.0] Nominal heating capacity 14.0 [6.2~16.0] Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 4.03/4.03 Running current (Cooling) 6.1/6.4 Power factor (Cooling) 95/96 Heating power consumption 3.80/3.85 Running current (Heating) 5.7/6.0 Power factor (Heating)
  • Page 22 Model FDUMVA602HES2R FDUMVA602HES2R Model Item FDUMA602R FDCVA602HESAR Nominal cooling capacity 14.0 [6.7~14.5] Nominal heating capacity 16.0 [6.3~16.5] Power source 3 Phase, 380-415V 50Hz/380V 60Hz 4.95/4.95 Cooling power consumption Running current (Cooling) 7.4/7.7 Power factor (Cooling) 97/98 Heating power consumption 4.75/4.91 Running current (Heating) 7.2/7.6 95/98...
  • Page 23 (b) Twin type Model FDUMVA402HESP2R (Indoor unit: 2 Units, Outdoor unit: 1 unit) FDUMVA402HESP2R Model Item FDUMA202R FDCVA402HESAR Nominal cooling capacity 10.0 [6.1~11.2] Nominal heating capacity 11.2 [6.0~12.5] Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 3.12/3.12 4.6/4.8 Running current (Cooling) Power factor (Cooling) 98/99...
  • Page 24 Model FDUMVA502HESP2R (Indoor unit: 2 Units, Outdoor unit: 1 unit) FDUMVA502HESP2R Model Item FDUMA252R FDCVA502HESAR Nominal cooling capacity 12.5 [6.7~14.0] Nominal heating capacity 14.0 [6.2~16.0] Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 4.47/4.47 Running current (Cooling) 6.6/6.9 Power factor (Cooling) 98/98 Heating power consumption...
  • Page 25 Model FDUMVA602HESP2R (Indoor unit: 2 Units, Outdoor unit: 1 unit) FDUMVA602HESP2R Model Item FDUMA302R FDCVA602HESAR Nominal cooling capacity 14.0 [6.7~14.5] Nominal heating capacity 16.0 [6.3~16.5] Power source 3 Phase, 380-415V 50Hz/380V 60Hz 5.00/5.00 Cooling power consumption Running current (Cooling) 7.3/7.7 Power factor (Cooling) 99/99 Heating power consumption...
  • Page 26 (c) Triple type Model FDUMVA602HEST2R (Indoor unit: 3 Units, Outdoor unit: 1 unit) FDUMVA602HEST2R Model Item FDUMA202R FDCVA602HESAR Nominal cooling capacity 14.0 [6.7~14.5] Nominal heating capacity 16.0 [6.3~16.5] Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 5.09/5.09 Running current (Cooling) 7.4/7.8 Power factor (Cooling) 99/99...
  • Page 27 (5) Wall mounted type (FDKN) (a) Twin type Model FDKNVA402HESP2R (Indoor unit: 2 units, Outdoor unit: 1 unit) FDKNVA402HESP2R Model Item FDKNA201R FDCVA402HESAR Nominal cooling capacity 10.0 [6.1~11.2] Nominal heating capacity 11.2 [5.6~12.5] Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 2.90/2.90 Running current (Cooling)
  • Page 28 Model FDKNVA502HESP2R (Indoor unit: 2 units, Outdoor unit: 1 unit) FDKNVA502HESP2R Model Item FDKNA251R FDCVA502HESAR Nominal cooling capacity 12.5 [6.5~14.0] Nominal heating capacity 14.0 [6.2~16.0] Power source 3 Phase, 380-415V 50Hz/380V 60Hz 4.14/4.14 Cooling power consumption 6.1/6.4 Running current (Cooling) 98/98 Power factor (Cooling) 4.39/4.39...
  • Page 29 (b) Triple type Model FDKNVA602HEST2R (Indoor unit: 3 units, Outdoor unit: 1 unit) FDKNVA602HEST2R Model Item FDKNA201R FDCVA602HESAR 14.0 [6.7~14.5] Nominal cooling capacity 16.0 [6.3~16.5] Nominal heating capacity Power source 3 Phase, 380-415V 50Hz/380V 60Hz Cooling power consumption 4.82/4.82 Running current (Cooling) 7.0/7.4 Power factor (Cooling) 99/99...
  • Page 34 ∼ ∼ ∼...
  • Page 37 2. MULTI-TYPE (V MULTI) PACKAGED AIR-CONDITIONER CONTENTS 2.1 GENERAL INFORMATION................37 2.1.1 Specific features ..................37 2.1.2 How to read the model name ..............37 2.1.3 Table of models ..................38 2.1.4 Table of system combinations ..............38 2.2 SELECTION DATA ..................39 2.2.1 Specifications .....................
  • Page 38: General Information

    GENERAL INFORMATION 2.1.1 Specific features Ideal for the installation conditions characteristic of larger rooms and L-shaped or other non-standard-shaped rooms, the Multi-Type V series allows an extensive degree of flexibility in the selection of indoor units. Specifically, the selection of indoor units with differing capacities and differing or similar types is supported, as is the selection of indoor units with similar capacities and differing types.
  • Page 39: Wall Mounted Type (Fdkn)

    2.1.3 Table of models Capacity Model Ceiling recessed compact type (FDTC) Ceiling recessed type (FDT) Ceiling suspended type (FDEN) Wall mounted type (FDKN) Satallite ducted type (FDUM) FDCVA402HESAR FDCVA502HESAR FDCVA602HESAR Outdoor unit to be combined (FDC) (4 Horse Power) (5 Horse Power) (6 Horse Power) 2.1.4 Table of system combinations Branch pipe set...
  • Page 40: Indoor Unit

    SELECTION DATA 2.2.1 Specifications (1) Indoor unit (a) Ceiling recessed compact type (FDTC) Model FDTCA201R Model FDTCA201R Item ( 1) Nominal cooling capacity ( 1) Nominal heating capacity Power source 1 Phase, 220-240 50Hz/220V 60Hz Powerful mode Hi: 46 Me : 42 Lo: 38 Noise level dB(A) Mild mode Hi: 46 Me : 38 Lo: 35...
  • Page 41: (B) Ceiling Recessed Type (Fdt)

    (b) Ceiling recessed type (FDT) Models FDTA201R, 251R Model FDTA201R FDTA251R Item ( 1) Nominal cooling capacity ( 1) Nominal heating capacity Power source 1 Phase, 220-240 50Hz/220V 60Hz Powerful mode Hi: 36 Me : 33 Lo: 32 Powerful mode Hi: 38 Me : 35 Lo: 33 Noise level dB(A) Mild mode Hi: 33 Me : 32 Lo: 31...
  • Page 42 Model FDTA301R Model FDTA301R Item ( 1) Nominal cooling capacity ( 1) Nominal heating capacity Power source 1 Phase, 220-240V 50Hz/220V 60Hz Powerful mode Hi: 38 Me: 35 Lo: 33 Noise level dB(A) Mild mode Hi: 35 Me: 33 Lo: 31 Unit:295 Exterior dimensions Height...
  • Page 43: (C) Ceiling Suspended Type (Fden)

    (c) Ceiling suspended type (FDEN) Models FDENA201R, 251R Model FDENA201R FDENA251R Item ( 1) Nominal cooling capacity ( 1) Nominal heating capacity Power source 1 Phase, 220-240V 50Hz/220V 60Hz Powerful mode Hi: 42 Me : 39 Lo: 38 Powerful mode Hi: 44 Me : 41 Lo: 39 Noise level dB(A) Mild mode Hi: 39 Me : 38 Lo: 37...
  • Page 44 Model FDENA301R Model FDENA301R Item ( 1) Nominal cooling capacity ( 1) Nominal heating capacity Power source 1 Phase, 220-240V 50Hz/220V 60Hz Powerful mode Hi: 44 Me: 41 Lo: 39 Noise level dB(A) Mild mode Hi: 41 Me: 39 Lo: 38 Exterior dimensions 1320 Height...
  • Page 45: (D) Wall Mounted Type (Fdkn)

    (d) Wall mounted type (FDKN) Model FDKNA201R Model FDKNA201R Item ( 1) Nominal cooling capacity ( 1) Nominal heating capacity Power source 1 Phase, 220-240V 50Hz/220V 60Hz Powerful mode Hi: 47 Me: 44 Lo: 41 Noise level dB(A) Mild mode Hi: 44 Me: 41 Lo: 38 Exterior dimensions Height Width...
  • Page 46 Model FDKNA251R Model FDKNA251R Item ( 1) Nominal cooling capacity ( 1) Nominal heating capacity Power source 1 Phase, 220-240V 50Hz/220V 60Hz Powerful mode Hi: 48 Me: 45 Lo: 42 Noise level dB(A) Mild mode Hi: 45 Me: 42 Lo: 39 Exterior dimensions Height Width...
  • Page 47: (E) Satillite Ducted (Fdum)

    (e) Satellite ducted type (FDUM) Models FDUMA202R, 252R, 302R Models FDUMA202R FDUMA252R FDUMA302R Item Nominal cooling capacity* Nominal heating capacity* Power source 1 Phase 220-240V 50Hz/220V 60Hz Noise level dB(A) Hi: 34 Me: 31 Lo: 28 Hi: 35 Me: 32 Lo: 29 Exterior dimensions Height Width...
  • Page 48: Outdoor Unit

    (2) Outdoor unit Model FDCVA402HESAR Model FDCVA402HESAR Item Power source 3 Phase, 380-450V 50Hz/380V 60Hz ( 1) Nominal cooling capacity 10.0 [6.1~11.2] ( 1) Nominal heating capacity 11.2 [5.6~12.5] Noise level dB(A) Exterior dimensions Height Width Depth Net weight Refrigerant equipment RM-B5125MDE31 compressor type &...
  • Page 49 Models FDCVA502HESAR, 602HESAR Model FDCVA502HESAR FDCVA602HESAR Item Power source 3 Phase,380-415V 50Hz/380V 60Hz ( 1) Nominal cooling capacity 12.5 [6.5~14.0] 14.0 [6.7~14.8] ( 1) Nominal heating capacity 14.0 [6.2~16.0] 16.0 [6.3~16.8] Noise level dB(A) Exterior dimensions Height Width Depth Net weight Refrigerant equipment RM-B5125MDE31 compressor type &...
  • Page 50: Operation Chart

    (3) Operation chart The Multi-Type V series is a system that allows for different models and capacities of indoor units to be connected so the individual operating characteristics of the indoor and outdoor are provided. Use the procedure shown in Item (c) to calculate the combined operating characteristics.
  • Page 51: (C) Calculation Of Total Operation Characteristics

    (c) Calculation of total operation characteristics Since the operation characteristics of series Multi depend on combination of indoor unit, calculate the total operation charac- teristics of the system by using the formulas below according to specifications of each indoor unit or outdoor unit. 1) 3 Phase models a) Total power consumption Total power consumption (kW) = Power consumption of outdoor unit + ∑...
  • Page 52 PACKAGED AIR-CONDITIONER Air-Conditioning & Refrigeration Systems Headquarters 16-5, 2-chome, Kounan, Minato-ku, Tokyo, 108-8215, Japan Fax : (03) 6716-5926 No.094(1.1A) R...