1 03 Technical data
Heat
output
Model
Max
kW
Sigma 20/40
11,7
Sigma 40/60
17,6
Gas supply pressures
Model
G20-NG
Sigma 20/40
Sigma 40/60
Model
Flow
1
Ø
Sigma 20/40
22
Sigma 40/60
22
Maximum working temperature 82°C, adjustable between 60°C and 82°C.
Heat
input
(net)
Min
Max
Min
kW
kW
kW
5,5
13,0
6,1
11,4
19,5
12,7
G31-LPG
mbar
mbar
20
37
20
37
Max. working
Connections
Return
Gas inlet
2
3
Ø
Ø
22
15
22
15
Sigma
Heat
input
(gross)
G20-NG
Max
Min
Ø
kW
kW
14,4
6,8
3,0
21,7
14,1
3,60
Burner gas pressures
G20-NG
Minimum
mbar
3,1
6,4
pressure
Protection
C.H.circuit
level
bar
3
IP 40
3
IP 40
Injectors
(mm)
G20 m
G31-LPG
Ø
Max
1,8
1,37
2,30
2,06
Nominal
Minimum
mbar
mbar
14,0
9,0
15,3
16,0
Boiler
water
Weight
contents
kg
litres
30
1,3
35
1,6
Gas flow rates
3
/h-NG
G31 kg/h-LPG
Min
Max
Min
0,64
1,02
0,48
1,34
1,53
0,99
G31-LPG
Nominal
mbar
36
36
Gas valve
Ø 1/2"
Honeywell
VK 4105 A
VK 4105 A