KitchenAid KAC-48 Technical Education page 37

Microwave oven / hood combination
Table of Contents

Advertisement

4.
To remove the primary or secondary
interlock switch:
a) Open the microwave oven door.
b) Remove the screw from the front of
the chassis for the switch you are re-
moving.
c) Depending on the switch you are re-
moving, rotate the switch holder lock-
ing cam in the direction of the arrow.
This will unlock the switch holder from
the chassis.
d) Remove the primary or secondary
inter-lock switch holder from the
oven.
Primary Interlock
Switch Holder
Screw
Secondary Interlock
Switch Holder Screw
e) Remove the primary or secondary in-
terlock switch from its holder. To re-
move the switch, refer to step 3.
f) Primary Interlock Switch: Press down
on the locking tabs, and disconnect the
orange (NC2), brown and white (NC4),
and black (C1) wires from the switch ter-
minals (see the upper-right photo).
Rotate Cam
g) Secondary Interlock Switch: Press down
Rotate Cam
REASSEMBLY NOTE: Be sure to rotate the
switch cam back to its original position after you
reinstall the switch holder on the oven chassis.
4-
Orange (NC2)
Brown and White
Black (C1)
Primary Interlock Switch
on the locking tabs, and disconnect the
blue & white (NC2) and blue & black
(C1) wires from the switch terminals.
Blue and White
Blue and Black
Secondary Interlock Switch

Advertisement

Table of Contents
loading

Table of Contents