Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
LINE FUSE
Refer to page 4-18 for the procedure for ac-
cessing the line fuse.
1.
Unplug microwave oven or disconnect
power.
2.
Disconnect one of the wires from the fuse
holder terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
fuse holder terminals. The meter should
indicate a closed (0 Ω) circuit.
WARNING
Electrical Shock Hazard
COOLING FAN MOTOR
Refer to page 4-19 for the procedure for ac-
cessing the cooling fan motor.
1.
Unplug microwave oven or disconnect
power.
2.
Disconnect one of the wires from the
cooling fan motor terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
cooling fan motor terminals. The meter
should indicate between 90 and 135 Ω.