Removing Cavity Thermostat #1, The Motor Capacitor, The Ac Line Filter And The Power Supply Cord - KitchenAid KAC-48 Technical Education

Microwave oven / hood combination
Table of Contents

Advertisement

REMOVING CAVITY THERMOSTAT #, THE MOTOR
CAPACITOR, THE AC LINE FILTER AND
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug microwave oven or disconnect
power.
2.
Remove the microwave oven from its
mounting location (see page 2-4 for the
procedure and reverse the procedure).
3.
Remove the cabinet from the oven (see
page 4-4 for the procedure).
Motor Capacitor
AC Line Filter
THE POWER SUPPLY CORD
Power Supply Cord
Cavity Thermostat #1
4.
To remove cavity thermostat #:
a) Disconnect the two wire connectors
from the cavity thermostat terminals.
b) Remove the two cavity thermo-
stat bracket nuts and remove the
thermostat.
Cavity Thermostat #1
Wire Connectors
To remove the motor capacitor:
5.
a) Discharge the capacitor by touching
the leads of a 20,000 Ω resistor from
each of the capacitor leads to the
chassis ground.
b) Disconnect the two wire connectors
from the capacitor terminals.
c) Remove the capacitor screw and re-
move the capacitor.
BR
YL
Screw
Motor Capacitor
4-
Bracket Nuts
Connectors

Advertisement

Table of Contents
loading

Table of Contents