INSTALLATION
MASONRY
CHIMNEY
Ensure that a masonry chimney meets the minimum
standards of the National Fire Protection Association
(NFPA) by having it inspected by a professional. Make
sure there are no cracks, loose mortar or other signs of
deterioration and blockage. Have the chimney cleaned
before the stove is installed and operated. When connect-
ing the stove through a combustible wall to a masonry
chimney, special methods are needed.
Ensure that an effective vapour barrier at the location
where the chimney or other component penetrates to
the exterior of the structure.
When referencing installation or connection to
masonry fi replaces or chimneys, the masonry
construction must or shall be code complying.
MASONRY
FIREPLACE
There are listed kits available to connect a stove
to a masonry fi replace. The kit is an adapter that
is installed at the location of the fi replace damper.
The existing damper may have to be removed to
allow installation.
Ensure that an effective vapour barrier at the location
where the chimney or other component penetrates
to the exterior of the structure.
When referencing installation or connection to
masonry fi replaces or chimneys, the masonry
construction must or shall be code complying.
When a metal prefabricated chimney is used, the manufacturer's installation instructions must be followed. You must also purchase and install the ceiling support
package or wall pass-through and "T" section package, fi restops (where needed), insulation shield, roof fl ashing, chimney cap, etc. Maintain proper clearance
to the structure as recommended by the manufacturer. The chimney must be the required height above the roof or other obstructions for safety and proper
draft operation. The space heater is to be connected to a factory-built chimney conforming to CAN/ULC-S629, Standard for 650
10
FACTORY
BUILT CHIMNEY
0
C Factory-Built Chimneys.