MAINTENANCE
Completely clean out entire unit
Inspect air tubes, baffl es and bricks
Adjust door catch / latch
Inspect condition and seal of:
Glass Gasket
Door Gasket
Paper Test
Check and lubricate door hinge + latch
Check glass for cracks
Clean blower motor
Inspect and clean chimney
28
Annual Maintenance
Annually
Replace any damaged parts.
If unable to obtain a tight seal on the door - replace door gasket seal.
Readjust latch after new gasket installed.
Perform paper test - replace gasket if required
Test the seal on the loading door with a paper bill.
Place a paper bill in the gasketed area of the door on a cold stove–close
the door.
Try to remove the paper by pulling.
The paper should not pull out easily, if it does, try adjusting the door latch,
if that doesn't solve the problem replace the door gasket.
Use only high temperature anti seize lube. (ie. never seize)
Replace if required.
Disconnect power supply.
Remove and clean blower.
*DO NOT LUBRICATE*
Annual professional chimney cleaning recommended.