Make Electrical Connection

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box and install a UL
listed or CSA approved ¹⁄₂" strain relief.
4. Run home power supply wiring through ¹⁄₂" strain relief into
terminal box.
A
B
B
I
A. Terminal box cover
B. Screws
C. Home power supply
"
D. ½
UL listed or CSA
approved strain relief
E. Terminal box
5. Use UL listed wire connectors and connect white wires (B)
together.
6. Use UL listed wire connectors and connect black wires (C)
together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
10
C
D
F
G
H
F. Black wires
G. White wires
H. UL listed wire connectors
I. Green (or bare) wires connected
to yellow-green wires
7. Connect green (or bare) ground wire from home power supply
to the 2 yellow-green ground wires (D) in terminal box using
UL listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Reconnect power.
Optional Power Cord Kit Installations
For optional power cord kit installations, follow the instructions
supplied with the power cord kit. See the "Assistance or Service"
section for information on ordering.
NOTE: Use only with range hood cord connection kits that have
been investigated and found acceptable for use with this model
range hood.
1. When using both upper and lower vent covers, push lower
cover down onto hood and lift upper cover to ceiling and
install with 2 - 2.9 x 6.5 mm screws.
NOTE: For vented installations, the upper vent cover may be
reversed to hide slots.
D
E

Complete Installation

1. For non-vented (recirculating) installations only, install
charcoal filters over grille on blower housing. See the "Range
Hood Care" section.
2. Install metal filters. See the "Range Hood Care" section.
3. Check the operation of the range hood blower and light. See
the "Range Hood Use" section.
NOTE: To get the most efficient use from your new range hood,
read the "Range Hood Use" section.

Install Vent Covers

C
C
A. Upper vent cover
B. Lower vent cover
C. 2.9 x 6.5 mm screws
D. Bracket