19. Reset the burner control by pressing the reset button
located on the burner control. If you do not know
where the control reset button is, do not touch any
part of the control system or wiring. Turn all gas
and electrical power off to the appliance and call a
qualified service technician.
20. Replace the upper front jacket panel.
1. Set the thermostat to lowest setting.
2. Turn off electric power to the appliance if service is to
be performed.
3. Remove front door.
OPERATING INSTRUCTIONS CONTINUED
To Turn Off Gas To Boiler
21. Observe several on and off cycles of the water heater.
If any light offs are excessively noisy or rough, or any
questionable boiler operation is noticed, immediately
turn off all gas and electrical power and call qualified
service technician.
22. Should overheating occur or the gas supply fail
to shut off, turn off the manual gas control to the
appliance.
4. Rotate gas main shutoff valves, located inside the
appliance, clockwise
"OFF". Make sure handle rests against stop.
5. Replace front door.
6. At the rear of the unit, rotate the pilot and main gas
valves clockwise
"OFF". Make sure handle rests against stop.
45
from "ON" position to
from "ON" position to