Thermal Solutions EVCA SERIES Installation, Operating And Service Instructions page 30

Condensing boiler
Table of Contents

Advertisement

GND TO
CHASSIS
120V-1PH-60HZ
SEE FIGURES 9a&9b FOR
SUPPLY POWER WIRING
ALARM SILENCE
PUSH BUTTON
ALARM BELL
(2)
TO VSD
TERMS.
(1)
1&2
DRY CONTACTS
FOR BOILER
STATUS
INDICATION
A2
A1
BOILER PUMP
M
PUMP MOTOR STARTER
5
9
CRA3
AND OVERLOAD RELAY
96
95
LT
BLOCKED AIR FILTER
NO
C
SWITCH AND LIGHT
115V TO 24V
115V TO 24V
TRANSFORMER
TRANSFORMER
GND TO
CHASSIS
OUTLET
SENSOR
INLET
SENSOR
PROG. SPARE OUTPUT
COLD AIR DAMPER,
SYSTEM PUMP BACKUP
OR ALARM
SYSTEM PUMP
LOCKOUT INDICATOR
MIXING VALVE
ACTUATOR
G
G0
Y
LINE TYPES:
FACTORY WIRING, LINE VOLTAGE
FACTORY WIRING, LOW VOLTAGE (SEE NOTE 2)
FACTORY WIRING, SPECIAL IGNITER
FIELD WIRING, LINE VOLTAGE
FIELD WIRING, LOW VOLTAGE
OPTIONAL WIRING
Q7800H1009 INTERNAL WIRING
G
G
L2
2
FUSE
L1
K3
29
2
4
SENSE
ALARM RELAY K2
3
K2
LINE VOLTAGE ALARM
30
31
4
K3
BLOWER MOTOR
32
K5
33
5
34
35
K5
K5
36
AUXILIARY RELAY
37
K3
38
6
21
K4
39
K4
40
7
41
K6
43
44
9
MAIN FUEL
45
VALVE(S)
K6
46
3
2
8
3
2
10
3
3
47
G
K2
48
49
2
HONEYWELL Q7800H
FLAME SAFEGUARD SUBBASE
50
PROGRAMMER CONTROL
RM7896D 1027
C
PR
BO
BC
BI
C
C
C
9
13
14
CRA
SO
1
5
9
13
14
CRA
SP
2
5
13
14
CRA
BP
3
9
13
14
CRA
VI
4
SPARE
5
9
13
14
CRA
LO
5
5
CONTROL RELAY OPTIONS
MS
MR
REMOTE CONTROL
OR
C-
REMOTE SETPOINT
C+
0-10 VDC INPUT
(VALID INPUT SIGNAL RANGE IS 1-9VDC)
SEE NOTE 2
RJ11
30
2
3
10
K1
K1
11
SENSE
11
LOW WATER CUTOFF
12
10
SENSE
BURNER ON/OFF
13
SWITCH
14
9
SENSE
15
WATER FLOW SWITCH
16
8
SENSE
17
GAS PRESS SWITCHES
18
7
SENSE
19
HIGH LIMIT
20
21
22
SENSE
6
COMBUSTION AIR
FLOW
23
24
PRIMARY
GAS RATIO
25
5
ACTUATOR
SENSE
MAIN FUEL VALVE
26
E/H
2
42
27
2
28
2
12
K1
3
11
CALL FOR
10
HEAT
AND
9
Pin 7
8
7
6
5
Pin 1
4
24VAC -
2
24VAC +
1
THERMAL SOLUTIONS
BOILER CONTROL
(TSBC)
24VAC -
AL
FUSE
CS
24VAC +
10
9
8
7
Pin 6
6
CA HL GP WF
OO V- V+ P- P+
5
4
Pin 1
3
2
1
LC
CH
O+
12 VDC
0.5A MAX TOTAL
O+
FOR SO, SP, BP,
O-
V1, & LO
O-
R+
R+
R-
R-
DP
LR
12 VDC
RO
1
(FIELD SUPPLIED
4
CONTACTS/SWITCHES)
LOCAL
C
SI
C
GND TO
RJ45
CHASSIS
P
2
1
MM 750-
MT-120
3
LOW WATER
VESTIBULE
CUTOFF
THERMAL FUSE
5
BURNER ON/OFF SWITCH
WATER FLOW SWITCH
NO
C
HIGH AND LOW GAS
HIGH
LOW
PRESSURE SWITCHES
NC
C
NO
C
HIGH LIMIT AND OPERATING
HIGH LIMIT
OPERATING LIMIT
TEMPERATURE SWITCHES
NC
NC
C
C
UNUSED OPERATING LIMIT
MANUAL
AUTO
COMBUSTION AIR FLOW
SWITCH
NO
C
SECONDARY
GAS
VALVE
L
L
VENT VALVE
(OPTIONAL)
N
N
GND TO
CHASSIS
INTERRUPTED
IGNITION PILOT
GAS VALVE
IGNITION XFMR
IGNITION PILOT
UV SCANNER
COMBUSTION BLOWER
SPEED CONTROL
CIRCUIT
VARIABLE
SPEED DRIVE
AC Tech SCF
(38)
1
2
5
12
2
(37)
2
OUTSIDE AIR
OUTSIDE AIR
SENSOR
RESET OPTION
REMOTE SYSTEM
SENSOR
DOMESTIC HOT WATER PRIORITY
DOMESTIC HOT WATER PRIORITY
LOCAL/REMOTE(REMOTE CONTROL OR REMOTE SETPOINT)
LOCAL/REMOTE(REMOTE CONTROL OR REMOTE SETPOINT)
REMOTE ON/OFF(ENABLE/DISABLE)
REMOTE ON/OFF(ENABLE/DISABLE)
2
SEE NOTE 3
3
REMOTE
SPARE INPUT
SPARE INPUT
TO K3
RELAY ON
FLAMESAFEGUARD
SUBBASE
TERM. 37 & 38

Hide quick links:

Advertisement

Table of Contents
loading