Indoor Unit Error Display - Klimairre KSIM018‐H210 Service Manual

Ksim series 3d dc inverter split wall-mounted type, units 18 – 24.000 btu/h; 230/208v, 60hz,1ph, r410a
Table of Contents

Advertisement

8.1 Indoor Unit Error Display

Display
E0
E1
E2
E3
E5
E6
P0
P1
P2
P4
Note: E4 & P3: Reserved function
EEPROM parameter error
Indoor / outdoor units communication protection
Zero-crossing signal error
Fan speed out of control
Open or short circuit of outdoor temperature sensor
Open or short circuit of room or evaporator temperature sensor
IGBT over-strong current protection
Over voltage or too low voltage protection
Temperature protection of compressor top.
Inverter compressor drive error