Installation Details; Tightening Connection; Connecting The Cables; Pipe Length And The Elevation - Klimairre KSIM018‐H210 Service Manual

Ksim series 3d dc inverter split wall-mounted type, units 18 – 24.000 btu/h; 230/208v, 60hz,1ph, r410a
Table of Contents

Advertisement

6. Installation details

6.1 Tightening Connection

Align the center of the pipes.
Sufficiently tighten the flare nut with fingers, and then tighten it with a spanner and torque wrench as
shown in Fig.
Outer diam.
Ф6.35mm
Ф9.52mm
Ф12.7mm
Ф16mm

6.2 Connecting the cables

The power cord of connect should be selected according to the following specifications sheet.

6.3 Pipe length and the elevation

Capacity
Btu/h
Gas
18K
1/2'' (Ф12.7)
24K
5/8'' (Ф16.0)
Tightening torque(N.cm)
1/4"
1570(160kgf.cm)
3/8"
2940(300kgf.cm)
1/2"
4900(500kgf.cm)
5/8"
7360(750kgf.cm)
Unit
9K
2
mm
1.5
Pipe size
Liquid
1/4'' (Ф6.35)
3/8'' (Ф9.52)
Additional tightening torque(N.cm)
Grade
12K
18K
24K
1.5
2.5
2.5
Standard
Max.
length
Elevation
(m)
B (m)
5
8
5
10
1960(200kgf.cm)
3430(350kgf.cm)
5390(550kgf.cm)
7850(800kgf.cm)
Max.
Additional
Length
refrigerant
A (m)
(g/m)
15
20
20
40
12