7.12 Timer function

7.12.1 Timing range is 24 hours, and the minimum resolution is 15 minutes.
7.12.2 Timer on. After turning off, the machine will turn on automatically when reaching the setting time.
7.12.3 Timer off. After turning on, the machine will turn off automatically when reaching the setting time.
7.12.4 Timer on/off. After turning off, the machine will turn on automatically when reaching the setting "on" time, and
then turn off automatically when reaching the setting "off" time.
7.12.5 Timer off/on. After turning on, the machine will turn off automatically when reaching the setting "off" time, and
then turn on automatically when reaching the setting "on" time.
7.12.6 The tolerance of Timer is 1 minute per hour.

7.13 Sleep function mode

7.13.1 Operation time in sleep mode is 7 hours. After 7 hours the machine quits this mode and turns off.
7.13.2 In cooling, heating or auto mode sleep function is available.
7.13.3 Operation process in sleep mode is as follow:
1)
After pressing ECONOMIC or SLEEP button on controller, the machine will turn into sleep mode.
2)
When cooling, the setting temperature rises 1℃(be lower than 30℃) every one hour, 2 hour later the
rising stops and indoor fan is fixed as low speed.
3)
When heating, the setting temperature descends 1℃(be lower than 30℃) every one hour, 2 hour later
the descending stops and indoor fan is fixed as low speed, and anti-cold-wind is available.
7.13.4 If user uses timer on function in sleep mode, sleep function will pause and not resume until reaches the setting
on time.
7.13.5 When user uses timer off function in sleep mode(or sleep function in timer off mode), if the timing time is less
than 7 hours, sleep function will be cancelled when reaching the setting time. If the timing time is more than 7
hours, the machine will not stop until reaches the setting off time in sleep mode.

7.14 Auto-Restart function

The indoor unit is equipped with auto-restart function, which is carried out through an auto-restart module. In case
of a sudden power failure, the module restores the setting conditions before the power failure. The unit will resume
the previous operation setting (including Mode, Fan speed, Temperature, ON/OFF) automatically after 3 minutes
when power returns.

7.15 Ionizer (Clean Air) function

1)
Clean Air function is available only when the aircon is on, and it's controlled through remote controller..
2)
After the Aircon being turned on, the Clean Air function is switched on when the aircon receives FRESH CODE at
first time, and ionizer is switched off when the aircon receives the CODE again. It's a circle.
3)
After starting the Clean Air function, the ionizer can work only when the indoor fan motor is running. If the indoor fan
motor is off, the ionizer also stops working, even though the Clean Air function is available.
4)
Switching the running mode will not stop the ionizer. When turning off the aircon, the ionizer is also turned off.

7.16 Self-clean function

1) Self-clean function is chosen through wire jumper J2 in indoor PCB, it's available when the unit has detected that J2
is on after getting through the power.
2) Self-Clean function is available only at cooling (including auto-cooling and turbo) and drying mode, when the user
press down the button "Self-Clean" on remote controller, the "Self-Clean" icon on LCD screen of indoor unit will keep
28