Cooling Mode - Klimairre KSIM018‐H210 Service Manual

Ksim series 3d dc inverter split wall-mounted type, units 18 – 24.000 btu/h; 230/208v, 60hz,1ph, r410a
Table of Contents

Advertisement

7.5 Cooling Mode

7.5.1 After starting, the operation frequency of compressor submits to following rule.
When the machine is running and ΔT(=room temp. – setting temp.) changes, the frequency of compressor will
rise or descend a grade (7 minutes after starting).
After start, if ΔT stays in a zone for 3 minutes, the frequency will change as follow:
Zone A : Current frequency rise a grade till the maximum grade.
Zone B: Elevate or keep or descend the frequency of compressor.
Zone H: Compressor stops after running as the minimum frequency for 60 minutes or ΔT is less than -2℃.
7.5.2 Indoor heat exchanger anti-freezing function.
If T2 is lower than 0℃, the compressor stops and resumes when T2>5℃.
7.5.3 Outdoor unit current control in cooling mode(refer to the parameter table)
Remark:
KSIM018-H217
KSIM024-H217
7.5.4 Rating capacity test function
1) Set the indoor unit with remote controller as: high fan, 17℃ in cooling mode, then press "TURBO" button on
controller 6 times or more within 10 seconds(make sure indoor unit receives these signals), the machine
will turn into rating capacity test mode, the buzzer will make a "di" sound for 2 seconds continuously. Also,
indoor fan will change to rating speed, the frequency of compressor will be fixed as rating value. Any
condition of above is not satisfied, the machine can not be turned into rating capacity test mode.
2) The machine will quit from the rating capacity test mode if running for 5 hours or changing fan speed or
setting temperature.
7.5.5 Turbo function(press the "TURBO" button on remote controller)
1)
Elevate current frequency to a higher grade.
2)
Indoor fan turns to turbo speed.
3.5
3.0
-0.5
-1.0
I3COOL
I2COOL
I1COOL
I1COOL
9.5A
11 A
A
B
H
comp. pause
freq. descends if curr. rises;
freq. remains if curr. descends
running normally
I2COOL
10.5A
12 A
I3COOL
12.5A
13A
22

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ksim024‐h210

Table of Contents