11.6.   R e-­‐charging   t he   r efrigerant  
                    NOTE:     If   r efrigerant   g as   i s   l ost   f rom   t he   m achine,   i t   m ay   b e   n ecessary   t o   u se   a  
STEP   # 1.   T ake   o ff   t he   f ront   h ousing.  
STEP   # 2.   F ind   t he   s ource   o f   t he   l eak   a nd   r epair   u sing   s pecific   r efrigerant   g rade   s older.    
STEP   # 3.   L ocate   t he   p inch-­‐off   t ubes   ( see   p icture   b elow)   a nd   s older   o n   s ervice   v alves.    
STEP   # 4.   C onnect   a   v acuum   p ump,   a nd   e vacuate   r efrigerant   s ystem   f or   2 0   t o   3 0  
minutes,   u ntil   1 5Pa~30Pa   o f   v acuum   a re   o btained.  
STEP   # 5.   C harge   t he   s ystem   w ith   t he   r efrigerant   c harge   l isted   o n   t he   r ating   l abel  
found   o n   t he   s ide   o f   t he   u nit.    
Step   # 6.   R eassemble.  
 
 
 
 
 
 
 
      Gas   d elivery   p orts  
 
Figure:  
 
 
 
 
 
 
 
                 
 
 
 
 
 
 
 
 
 
Service   M anual   I deal   A ir   C G2   C ommercial   G rade   D ehumidifier    
Sunlight   S upply,   I nc.  
Qualified   R efrigeration   T echnician   t o   c orrect   t he   p roblem.   C ontact  
Ideal   A ir   S upport   f or   m ore   i nformation.    