Response:
Note:
If the input m is 0, the Video & Audio outputs will be blanked
Command:
Response:
4.1.6
Query Audio & Video ties:
Command:
Response:
Command:
Response:
4.2 Preset Save and Recall Functions
Command:
Response:
Command:
Response:
4.3 Power Functions
Command:
Response:
The Power ON Command can take up to 5 seconds to complete.
Notice
Upon powering up the unit will recall the previous state of each
output prior to powering off and restore each connection
Command:
Response:
Variation:
Command:
Response:
COn,m«
CO*,m«
Stands for Connect All both A&V Outputs to input m
CO1,m« CO2,m« CO3,m« CO4,m«
COn«
Stands for Connect Output Audio & Video Query
CVn,m« CAn,m«
CO*«
Stands for Connect All Output Audio & Video Query
CV1,m« CV2,m« CV3,m« CV4,m«
CA1,m« CA2,m« CA3,m« CA4,m«
PRx«
CV1,m« CV2,m« CV3,m« CV4,m«
CA1,m« CA2,m« CA3,m« CA4,m«
PSx«
PSx«
PW1«
PW1«
CV1,m« CV2,m« CV3,m« CV4,m«
CA1,m« CA2,m« CA3,m« CA4,m«
PW0«
PW0«
PW«
PWx«
Genesis™ Series 4x4 AV Matrix Switches
Stands for Preset Recall. x = preset 1~ 8
Stands for Preset Save. x = preset 1~ 8
Response sent after current tie pattern is saved
Stands for Power On
Stands for Power Off
Stands for Power Query
x=0 (off), or 1 (on)