Fc Switch Blade Installation - Fujitsu Siemens Computers PRIMERGY BX600 S2 Operating Manual

Hide thumbs Also See for PRIMERGY BX600 S2:
Table of Contents

Advertisement

FC Switch Blade
Configuration with a combination of 2-way server blades and 4-way server
blades
The illustration below shows the assignment of FC switch blades to the fabric
ports of the server blades in a configuration with two 4-way server blades and
six 2-way server blades.
FC switch blade NET3
A B A B A B A B A B A B A B A B A B A B
Figure 63: Fabric port assignment with 4-way and 2-way server blades
I
When using the 12-port version the fabric ports of the 2-way server
blades 3 and 4 (slots 9 and 10) are not available.
10.3

FC switch blade installation

V
CAUTION
FC switch blades must always be installed in slot NET3 first (see
page
108).
The installation and removal of FC switch blades takes place in the same way
as the installation of fibre channel pass-thru blades (see
PRIMERGY BX600 S2 Basic Unit
4-way
4-way
Server
Server
Blade 2
Blade 1
FC switch blade installation
FC switch blade NET4
page
121).
111

Advertisement

Table of Contents
loading

Table of Contents