EDID Modes
The diagram below illustrates the 4 DIP switch bank. The 8 DIP switch bank
functions are outlined later on this page.
1 2 3 4
Use DIP switch 3 to set the desired EDID mode.
LOCAL EDID Mode (Switch 3=OFF) DEFAULT
•
EDID that is stored in the LOCAL memory location is passed to all inputs.
•
By default, during each power on process the connected display's
EDID will be automatically copied to each of the input's LOCAL EDID
locations.*
•
The EDID stored in the LOCAL locations can be overwritten with another
EDID from the following locations (These options can only be initiated by
using RS-232 serial communication commands) :
•
Built-in EDID memory bank (up to 7 EDID records can be stored)
•
EDID collected directly from the input display*
•
Externally uploaded via the RS-232 command set (see p. 13)
*For the default EDID writing process to be successful the connected display
must be powered on.
DS (Down Stream) EDID Mode (Switch 3=ON)
•
EDID is passed directly from the connected display to the currently active
input. Note: HDCP is supported in this mode only.
EDID MODES
11
DIP SWITCH
1
2
3
4
Function
IR Channel
IR Channel
EDID Mode
N/A