Wand Emulation Interface
9 - 7

Convert All Bar Codes to Code 39

By default, the Wand Emulation interface sends data to the attached host in the symbology decoded. This can
present a problem for customers with legacy systems that do not recognize some newer symbologies (for example,
GS1 DataBar, formerly RSS).
Enable this parameter to ignore the decoded symbology, and output data as if it were a Code 39 bar code.
Lowercase characters in the original data stream transmit as uppercase characters. This also allows ADF
formatting.
If you enabled
Ignore Unknown Characters on page
9-6, characters that do not have a corresponding character in
the Code 39 symbology set are replaced by a space.
If you disabled
Ignore Unknown
Characters, and characters that do not have a corresponding character are
encountered, the scanner emits an error beep and discards the data.
ADF Note: By default, the Wand Emulation interface does not allow ADF rules to process scanned data. Enabling
this parameter allows ADF rules to process the scanned data (See
Chapter 13, Advanced Data
Formatting).
Enable Convert to Code 39 for Wand Host
*
Disable Convert to Code 39 for Wand Host