Gas Consumption; Operating Your Fire; The Oxysafe Flame Sensing And Flue Blockage Safety System - Valor Fires 963 Installer And Owner Manual

Inset live fuel effect gas fire incorporating the valor fires fireslide control, fitted with one of the following fascia: homeflame dream or homeflame petrus
Table of Contents

Advertisement

Gross figures
Has a maximum natural gas input of 3.9kW
Has a maximum natural gas output of 3.1kW
Has a minimum natural gas input of 2.3kW
Has a minimum natural gas output of 1.78kW
Net figures
Has a maximum natural gas input of 3.51kW
Has a maximum natural gas output of 3.1kW
Has a minimum natural gas input of 2.07kW
Has a minimum natural gas output of 1.78kW
When operating your fire for the first time, some vapours may be given off which may
cause a slight odour and could possibly set off any smoke alarms in the immediate
vicinity. These vapours are quite normal with new appliances. They are totally harmless
and will disappear after a few hours use.
Valor Fires considers all surfaces as working surfaces (which means they get hot)
with the exception of those areas intended to be touched by the owner during normal
use.

The Oxysafe flame sensing and flue blockage safety system.

For your safety, this appliance is fitted with a flue blockage safety device which will
shut down the appliance in the event of abnormal flue conditions. This device is
NOT a substitute for an independently mounted Carbon Monoxide detector.
The device will also automatically shut off the gas supply to the fire if the pilot flame
goes out due to lack of oxygen or for any other reason.
If this device starts to repeatedly shut off the gas, get expert advice.
This device incorporates a probe which senses that the heat from the pilot flame is
correct. If this probe is cool, the device will prevent any gas flow unless the control
knob is kept depressed at the ignition position.
If, for any reason, the flames go out when the fire is hot or if the fire is turned off
when hot, always wait at least three minutes before attempting to relight.
©
Baxi Heating U.K. Limited 2010.
OWNER GUIDE

GAS CONSUMPTION

OPERATING YOUR FIRE

PLEASE NOTE
Page 53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents