INSTALLER GUIDE

11.3 Inlet pressure check.

The appliance is pre-set to give the correct heat
input at the inlet pressure shown in section 3 of
this manual. No adjustment is necessary.
1. Check the inlet pressure by fitting a pressure
gauge at the test point. The test point is on the
inlet 'T' connector (See figure 25). Check the
pressure with the appliance alight and set at
maximum output.
2. After checking, turn off the appliance. Remove
the pressure gauge and replace the test point
sealing screw.
When the above checks from section 11.2 and
11.3 have been completed close the isolating
valve on the inlet 'T' connector.
Figure 25.

12. FITTING THE CERAMIC FUEL EFFECT

The installer and owner guide for the ceramic fuel effect is supplied with the ceramic
fuel effect. It is important that the fitting guide for the ceramic fuel effect be placed
inside or attached to this guide and handed to the customer following completion of
the 'Final review' section.

13. FITTING THE WINDOW

1. Locate the window assembly as in figure 26.
2. Apply a small amount of pressure
to the base of the window assembly
to overcome resistance from the
window gasket. With the base of
the window assembly close to the
fire body insert and secure the
window assembly with the two
knurled screws removed previously.
Figure 26.