Torque Sensor Circuit Board - Bunn CDS-2 Operating & Service Manual

Hide thumbs Also See for CDS-2:
Table of Contents

Advertisement

SERVICE (cont.)

TORQUE SENSOR CIRCUIT BOARD

FIG. 48 TORQUE SENSOR CIRCUIT BOARD
Location:
The torque sensor circuit board is located on the
rear of the cooling drum mount just left of center.
Test Procedures:
1. With the ON/OFF switch and Auger switch in the
"ON" position and the ICE/OFF/NO-ICE switch in
the "ICE" position check the L.E.D. on the control
panel.
2. The L.E.D. for the torque sensor is located be-
tween the appropriate auger switch and the ice
switch.
3. If the L.E.D. flashes one time every four seconds
the auger is not turning. If the L.E.D. flashes three
times every four seconds the torque is less than
possible. If the L.E.D. flashes four times every four
seconds the torque is greater than possible.
4. If the L.E.D. flashes three times every four sec-
onds, four times every four seconds or one time
every four seconds with the auger turning, replace
the torque sensor circuit board.
Removal and Replacement:
1. Remove the two #8-32 locking screws securing
the auger motor cover to the cooling drum mount.
2. Remove the cover and set aside for reassembly.
3. Remove the #8 locking screw on the lower right
side of the auger motor mounting bracket secur-
ing the auger motor run capacitor. Set capacitor
aside with wires attached.
4. Disconnect the auger motor plug from the connec-
tor on the main wiring harness.
5. Remove the three remaining #8 locking screws
securing the auger motor mounting bracket to
cooling drum mounting bracket.
6. Remove motor with mounting bracket, drip tray,
split pin and torsion spring bearings as an assem-
bly and set aside for reassembly.
NOTE: When removing or installing the motor be sure
the split pin in the motor shaft is turned to a position
that will clear the torque sensor circuit board.
7. Disconnect the plug from the dispenser main
wiring harness to the torque sensor circuit board.
8. Remove the #8-32 locking screw and washer
securing torque sensor circuit board to the cooling
drum mount.
P1341
9. Remove torque sensor circuit board and discard.
10. Install new torque sensor circuit board in the slot
in the rear of the cooling drum mount and secure
with a #8-32 locking screw and washer.
11. Refer to Fig. 49 and reconnect the wires.
12. Reinstall motor with mounting bracket, drip tray,
split pin and torsion spring bearings using three
#8 locking screws onto the cooling drum bracket.
13. Install the auger motor capacitor on the lower right
side of the auger mounting bracket using the
remaining #8 locking screw.
14. Connect the auger motor terminal to the terminal
on the main wiring harness.
15. Refer to Fig. 49 when reconnecting the wires.
16. Position the auger motor cover on the cooling drum
mount and secure with two #8-32 locking screws.
FIG. 49 TORQUE SENSOR CIRCUIT
48
BOARD TERMINALS
P1328
27646 122200