Bunn CDS-2 Operating & Service Manual page 33

Hide thumbs Also See for CDS-2:
Table of Contents

Advertisement

SERVICE (cont.)
COMPRESSOR & COMPONENTS (CDS-3) (cont.)
Compressor Start Capacitor:
WARNING: The compressor start capacitor must be
properly discharged before proceeding.
1. Disconnect the two leads on the compressor start
capacitor.
2. Loosen the capacitor retaining strap and remove
the capacitor.
3. Securely install new start capacitor under the
retaining strap.
4. Refer to Fig. 18 and reconnect the wires to the start
capacitor.
Compressor Run Capacitor:
WARNING: The compressor run capacitor must be
properly discharged before proceeding.
1. Disconnect the three leads from the compressor
run capacitor.
2. Loosen the capacitor retaining strap and remove
the capacitor.
4. Securely install new run capacitor under the re-
taining strap.
5. Refer to Fig. 18 and reconnect the wires to the relay.
BLK to Compressor
Relay T1
BLK
START
FIG. 18 COMPRESSOR CAPACITOR TERMINALS
Compressor Start Relay
WARNING: The compressor start capacitor must be
properly discharged before proceeding.
1. Disconnect the wires from the compressor relay.
2. Remove the #6-32 screw securing the relay to the
rear of the component bracket.
3. Remove and discard relay.
4. Install new relay on the rear of the component
bracket and secure with a #6-32 screw.
5. Refer to Fig. 19 and reconnect the wires.
BLK to Compressor
Relay T6
BLK to Compressor
Relay T2
RUN
P1817
T4 WHI from Compressor
and Main Harness
T4 BLK from Run Capacitor
T5 BLK from Compressor
Thermal Overload Protector
and Main Harness
T1 BLK from Start Capacitor
T2 BLK from Run Capacitor
T2 Red from Compressor
FIG. 19 COMPRESSOR RELAY TERMINALS
Compressor Thermal Overload Protector: Refer to FIG.
17
1. Remove terminal cover retainer (7) and terminal
cover (6).
2. Remove the wire from thermal overload protector
from the compressor wiring harness to the thermal
overload protector.
3. Remove overload protector retainer (5) and ther-
mal overload protector (4) as an assembly
4. Remove retainer (5) from overload protector (4)
and discard overload protector.
5. Install retainer (5) on new overload protector (2).
6. Install retainer (5) and overload protector (4) on
the compressor terminal bracket.
7. Refer to Fig. 20 and reconnect the thermal over-
load protector wires.
8. Reinstall terminal cover (6) and cover retainer (7).
FIG. 20 THERMAL OVERLOAD PROTECTOR
33
BLK to Compressor Relay T5
TERMINALS
P1820
P1821
27646 122200

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cds-3

Table of Contents