SERVICE (cont.)

FUSE AND FUSE HOLDER

FIG. 33 FUSE HOLDER
Location:
The fuse holder is located inside the dispenser on
the upper left side of the component bracket just below
the circuit breaker.
Test Procedures:
1. Disconnect the dispenser from the power source.
2. Remove cap and fuse from fuse holder.
3. Remove fuse from the cap.
4. Check for continuity through the fuse.
If continuity is present as described, reinstall the fuse,
the fuse is operating properly.
If continuity is not present as described, replace fuse.
Removal and Replacement:
Fuse:
1. Remove the cap from the fuse holder.
2. Remove fuse from the fuse holder, inspect, if
blown discard.
3. Install new 5 amp fuse in the fuse holder
4. Reinstall fuse holder cap.
Fuse Holder:
1. Disconnect the wires from the rear of the fuse
holder.
2. Remove nut securing the fuse holder to the com-
ponent bracket.
3. Push fuse holder through the hole in the compo-
nent bracket.
4. Install new fuse holder and fuse through the hole
in the component bracket.
5. Secure the fuse holder to the component bracket.
6. Refer to Fig. 34 and reconnect the wires.
WHI/GRN from Main
H a r n e s s / O N / O F F
Switch
P1342
FIG. 34 FUSE HOLDER TERMINALS
40
WHI/GRN from Main
Harness/Control Board
P1331
27646 022500