SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND. In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
CAUTION – Improper electrical installation will damage components. An electrician must provide electrical service as specified below. Model ULTRA-2, This dispenser has an attached cordset and requires a 2-wire, grounded, individual branch circuit rated 120 volts ac, 15 amp, single phase, 60 Hz. The mating connector must be a NEMA 5-15R.
INITIAL SETUP CAUTION – The dispenser is very heavy! Use care when lifting or moving it. Use at least two people to lift or move the dispenser. 1. Set the dispenser on a sturdy counter top. The dispenser requires a minimum of 6.0" air clearance at the rear of the dispenser.
Page 5
INITIAL SETUP (CONT.) 9. Align the auger shaft with the flat fin of the auger. Push the augers as far as they will go and rotate them so the flat fin is fac- ing up. 12. Slide them into place and push them down until the hopper lock plungers snap into place.
There are five of these switches that will be used for the operation of the dispenser. switch (upper left corner of the control pad) This switch is the ON/OFF toggle switch which powers up the dispenser and the LCD display. When ON the Date and Time toggle back and forth continously except during programming.
Using the menu-driven display on the front of the dispenser, the operator has the ability to alter or modify various parameters such as beverage consistency and set day/night “ON/OFF” times. The operator is also prompted to check a variety of periodic service functions or even a step-by-step cleaning routine. There is also the oppor- tunity to return all changes back to factory default settings.
During normal operations, the Date, the Time, and the Serial Number toggle back and forth continuously. The following function screens are in the order they appear from the menu display. Each screen will have instructions and procedures to program the various functions of the dispenser. HOME SCREEN Displays the TIME, DATE, SERIAL NUMBER and ASSET NUMBER which toggle back and forth continuously.
Page 9
Cleaning Guide This function leads the operator through a nine step cleaning process when answered YES (“ICE”). Depress GOURMET to display the next cleaning instruction. When entering this mode, the refrigeration system will automatically turn OFF. After step when hoppers are drained, the augers will turn OFF.
Set Consistency This function allows the operator to adjust the ice consistency, or torque of each auger when answered YES (“ICE”). Two screens will appear for left and right. The operator can scroll through a range of a minimum of1 (ULTRA) to a maximum of 16 (ICE).
Test Augers This function tests the operation of forward and reverse of each auger motor. Left auger appears first. Press the ICE hidden switch to toggle between OFF, FORWARD and REVERSE. Press GOURMET hidden switch to repeat the operation for the right auger motor. A one minute time out will return to the Home Screen. TEST AUGERS ? Y E S LEFT AUGER TEST...
Password From this screen, the operator must know the password before moving on to the remaining functions. The range is from 0 - 9999 with the factory default being 0. Set Night Time/Set Day Time The setting of the Day/Night mode allows the dispenser to “power down” during off hours. The bottom corners displaying “ICE”...
This feature allows the machine to defrost the product during day time operation. The defrost minutes setting will select the defrost time period. The freeze minutes setting will select the freeze time between defrost periods. These modes when activated will function anytime the machine is in day mode operation. The machine will automatically stay in the freeze mode for 2 hours after waking up from the night time mode.
Page 14
Day To Clean Off (formerly Days...Disabled) This function allows the operator to program a cleaning schedule from 1 to 14 days. The default screen is 0 or DISABLED. Selecting - or ULTRA will prompt the screen Days To Clean. Once a number of days is selected the screen will prompt two functions, CLEAN MESSAGE ONLY or CLEAN LOCKOUT.
Page 15
Switches Enabled This function allows the operator to lockout the touch pad. Selecting + (ON) provides no time delay on switches except for the center (GOURMET) hidden switch. Selecting - (LOCKOUT) provides a five second hold to wake up the touch pad and a two minute time frame from last button pressed to make adjustments before returning to sleep mode (five second hold).
Page 16
Restore Default? Answering YES (ICE) to this function returns the unit back to preset factory constants. 1. Set Consistency ? 10 2. Set Night Time - DISABLED 3. Set Day Time - DISABLED 4. 6 Month PM - ENABLE 5. Days...Disabled - DISABLED 6.
Page 17
TEMP & TORQUE Press and hold for five seconds the ULTRA and ICE hidden switches to display the TEMP & TORQUE. The temperature of each cooling drum and the hot gas temperature will toggle back and forth. The auger torque is displayed continuously.
Wait for the liquid to freeze to the desired consistency. HINTS – Bunn-O-Matic recommends that the product in the dispenser be thawed each day, usually overnight. The ice granules get too large and a consistent product is difficult to maintain if left frozen for an extended period of time.
OTHER RECOMMENDATIONS FOR YOUR DISPENSER • Whether liquid concentrate or granulated powder, all product must be thoroughly mixed BEFORE adding it to the hoppers. • For best results with granita-type products, use only products with an apparent brix of 12 or higher. Some products may work with an apparent brix as low as 9.
RECOMMENDED DAILY CLEANING NOTE – Turn the power OFF to the dispenser before proceeding. 1. Empty all product from the hoppers. Disconnect the hopper lid lamp cords and remove the lids. 2. Depress the hopper lock plunger. Lift the hopper up slightly.
INSTALLATION 1. Install the seals over the flange at the rear of the cooling drums and press the seals firmly into place as shown. 4. Thoroughly rinse the hoppers and install them over the augers and cooling drums. 7. Position the faucet seal and re- turn spring in the faucet valve.