INITIAL SETUP
CAUTION – The dispenser is very heavy! Use care when lifting or moving it. Use at least two people to lift or
move the dispenser.
1.
Set the dispenser on the counter where it will be used. The CDS-3 dispenser requires a minimum of 6.0" air
clearance on both sides and at the rear of the dispenser. For optimum performance, do not let warm air from
surrounding machines blow on the CDS-3 and DO NOT REMOVE VINYL DEFLECTOR.
NOTE – The dispenser should be level or slightly lower in front for proper operation.
6.0"
MIN.
2.
Remove all shipping material, including the compressor support eye-bolts, the cooling drum supports, the
"Do Not Lift Here" signs from the cooling drums, and the "Rinse Before Using" signs from each hopper.
NOTE – Use BOM M2550.0000 lubricant where specified.
3. Squeeze some lubricant into
hand.
6. Press the seals firmly into
place.
6.0"
MIN.
DO NOT REMOVE
4. Apply a thin film of lubricant to
each cooling drum seal.
7. Apply a thin film of lubricant to
the inside of each auger shaft
seal.
6.0"
MIN.
Vinyl Deflector
5. Install the seal over the flange
8. Install the seals on the auger
6
at the rear of each cooling drum
as shown.
shafts. Wipe the cooling drums
to remove any lubricant.