Jøtul C 550 Rockland Installation And Operating Instructions Manual page 9

Hide thumbs Also See for C 550 Rockland:
Table of Contents

Advertisement

Clearance to Combustible Materials
• There may be no combustible materials located
anywhere within 36" (914 mm) of the front of the
fireplace insert. This precaution includes items
such as drapes or doors that could swing into the
area within 36" of the insert.
• Specific clearance (open space) must be main-
tained between the fireplace insert and combus-
tible materials located above and to the side.
See figures 5-6 for minimum dimensions.
Minimum Clearances
Clearances are measured from the hearth surface,
door opening, or centerline as noted below.
A: A: A: A: A: Hearth Protection, width from centerline: .........
........................................................ 18 1/2" (470 mm)
B: B: B: B: B: Hearth Protection, forward from door opening:
.................................. US: 16" / CAN: 20"(508 mm)
C: C: C: C: C: To Side Trim, 1" max. thickness , from centerline
.............................................................. 21 3/4"
D: D: D: D: D: To Side Room Wall, from centerline: .....................
............................................................ 54" (1372 mm)
E: E: E: E: E: To Top Trim, 1" max. thickness, from hearth:
..................... US: 51 3/4" / CAN: 57 1/2" (1460 mm)
F: F: F: F: F: To Mantel , 3 1/2" max. depth, from hearth:
..................... US: 51 3/4" / CAN: 57 1/2" (1460 mm)
To Mantel, 11 1/2" max. depth, from hearth
..................... US: 57 3/4" / CAN: 63 1/2" (1613 mm)
See fig. 7 for clearances with Mantel Heat Shield.
B
A
Figure 6. Minimum clearance to combustible materials.
(552 mm)
F
E
C
D
Mantel Clearances
Clearance reduction to mantel construction may be
made in conformance to NFPA 211 or CAN/CSA B365.
MANTEL
11.5”
A
B
C
D
E
A
B
U.S:
57 3/4"
56 1/4"
CAN: 63 1/2"
62"
161.3 cm 157.4 cm 153.7 cm
U.S. & CAN: With Mantel Heat Shield 156448
48"
46 1/2"
127.9 cm
118.1 cm
Figure 7. Mantel Clearance Detail - measured from
the hearth surface to the lowest mantel surface.
Jøtul C 550 Rockland
AREA
3.5”
5.5”
7.5”
9.5”
C
D
54 3/4"
53 1/4"
51 3/4"
60 1/2"
59"
57 1/2"
150 cm
146 cm
45"
43 1/2"
114.3 cm 110.4 cm 106.6cm
E
42"
9

Advertisement

Table of Contents
loading

Table of Contents