Gasket Replacement
See the chart below for replacement gasket specifi-
cations. See also figs. 19-20 for locations.
1. Remove the old gasket material with a pliers and
thoroughly clean the channel with a wire brush.
2. Lay out the new gasket around the channel to
determine length. Trim the gasket to leave 1" excess.
3. Apply a small bead of gasket or furnace cement
in the channel.
4. Lightly press the new gasket into the channel,
being careful to avoid compressing or stretching
it. Trim the gasket further as necessary to allow
the tail end to slightly overlap the other end.
5. Wait ten minutes to allow the cement to set and
then close and latch the doors. Reopen the doors
and use a damp cloth to wipe away any excess
cement that may be squeezed out from under the
gasket.