Assembling Vent Pipes - Majestic 300DVBLN/PSC Installation And Operating Instructions Manual

Dvbl7 series direct vent gas fireplace
Table of Contents

Advertisement

VentInG InStaLLatIon InFormatIon
Termination Clearances
Termination clearances for buildings with combustible and noncombustible exteriors.
Inside Corner
G
V
Balcony -
with no side wall
V
M =
Combustible &
Noncombustible
12" (305 mm)
*note: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions specified for vinyl or
non-vinyl siding and soffits. 1. There must be a 3' (914 mm) minimum between termination caps. . All mechanical air intakes within 10' (1 m) of a
termination cap must be a minimum of 3' (914 mm) below the termination cap. 3. All gravity air intakes within 3' (914 mm) of a termination cap must
be a minimum of 1' (305 mm) below the termination cap.
GeneraL InFormatIon aSSemBLInG Vent pIpeS
uSa Installations
The venting system must conform to local codes and/or
the current National Fuel Code ANSI Z3.1/NFPA 54.
Only venting components manufactured or approved by
Vermont Castings Group may be used in Direct Vent sys-
tems.
canadian Installations
The venting system must be installed in accordance with
the current CSA-B149.1 installation code.
FLex Vent pIpeS
Secure flex vent pipe in place with a hose clamp (pro-
vided).
*Be sure the flex pipe overlaps at least 1" (5 mm) onto
the collars of the fireplace and termination. If the termina-
tion has an internal bead, be sure to overlap and secure
1" (5 mm) past the bead.
74D3001
Outside Corner
G =
Combustible
6" (152 mm)
V
Noncombustible
2" (51 mm)
Balcony -
with perpendicular side wall
M
Combustible &
Noncombustible
M = 12" (305 mm)
P = 6" (152 mm)
F =
Combustible
6" (152 mm)
Noncombustible
2" (51 mm)
F
M
V
P
Figure 7 -
Termination Clearances
* Be sure the vent is actually crushed before proceeding.
Apply a tug to be sure the vent will not slip off the collars.
Repeat process with 7" flex vent pipe. The same proce-
dure must be performed on the vent side.
Figure 8 -
Secure Flex Pipe with
Hose Clamps
DVBL7 Series Gas Fireplace
Alcove Applications*
D
C
V
O
E
= Min. 2" (51 mm) for
non-vinyl sidewalls
Min. 12" (305 mm) for
vinyl sidewalls
O
= 8' (2.4 m) Min.
No.
of Caps
D
Min.
1
3' (914 mm)  x D

6' (1.8 m)
3
9' (.7 m)
4
1' (3.7 m)
D
= # of Termination caps x 3
Min.
C
= ( / # termination caps) x D
Max.
Hose Clamp
C
E
C
Max.
Actual
1 x D
Actual
/3 x D
Actual
1/ x D
Actual
Actual
584-15
FP336
13