DVBL7 Series Gas Fireplace
LIGhtInG pILot For the FIrSt tIme
approVeD LeaK teStInG methoD
You may check for gas leaks with the following methods
only:
• Soap and water solution
• An approved leak testing spray
• Electronic sniffer
never check for gas leak with open flame!
Check for gas leaks in each of the following locations:
• Pipe from the gas supply line connection to the gas valve
• Burner connections
• Pilot
• Each joint or connection
the control has an interlock device that does not allow the lighting of the fireplace up to the
moment the safety device of the flame has not interrupted the gas flow. after that period of
time (when the magnet is closed), it is possible to start the lighting operation.
the gas control knob is designed to be operated by hand. Do not use any tools during this
operation. Damaged knobs may result in serious injury.
1. Depress and turn knob counterclockwise
to pilot position.
. D e p r e s s f u l l y a n d h o l d p i l o t g a s
knob. Depress piezo igniter as many
t i m e s a s n e e d e d t o i g n i t e p i l o t .
Keep knob fully depressed for a few sec-
onds. Release and check that pilot continues
to burn.
If the pilot does not stay lit, repeat steps 1 and
.
30
operatInG InStructIonS - mILLIVoLt
• Field made joints / gas shutoff valve
• Factory made joints
• All joints on valve and control body

LIGhtInG pILot

If using a soap and water
solution to test for leaks, Do
not spray solution onto control
body.
NOTE: Remove any excessive pipe
compound from the connections.
Excessive pipe compound can set off
electronic sniffers.
P I L
O T
Pilot Position
FP1935
control knob pilot
74D3001