Allied Telesis AT-9006T Installation Manual page 37

Gigabit ethernet switches
Table of Contents

Advertisement

6. Mount the switch in the rack using standard screws (not provided).
Caution
Air vents must not be blocked and must have free access to the
room ambient air for cooling.
7. If you purchased a redundant power supply (RPS) unit for the switch,
connect the RPS unit to the R.P.S. Input connector (Figure 4) on the
rear of the switch by following the directions included with the RPS
stem.
Note
If you intend to use a redundant power supply (RPS) with the
switch, check to be sure that the cable with the RPS unit is
compatible with the RPS Input Port on the switch. The pin
assignments for the connector are provided in Appendix A.
8. Apply AC power to the switch by plugging the power cord into the AC
power connector on the back panel of the unit (shown in Figure 4)
and plugging the other end into a power outlet.
Warning
The power cord is used as a disconnection device. To de-energize
equipment, disconnect the power cord. "
As power is applied to the switch, the Fault LED (shown in Figure
5) flashes as the switch runs a series of internal self tests. After the
switch has finished running its self tests, the Fault LED will stop
flashing and will remain OFF. Refer to the section System and
Port LEDs on page 19 for information on all of the system and
port LEDs.
9. Connect the data cables, making sure each connection has a good
valid link and that the switch is receiving packets.
10. Go to the procedure Starting a Local Omega Management Session
on page 41 to access the Omega management interface on the
switch.
AT-9006 Series Installation Guide
"
13