Page 2
Copyright 2000 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA 94086, USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Electrical Safety and Emission Compliance Statement Standards: This product meets the following standards. U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
AT-9006 Quick Install Guide Technical Support E-mail Addresses United States and Canada Latin America, Mexico, Puerto Rico, Caribbean, and Virgin Islands United Kingdom, Sweden, Norway, Denmark, and Finland Returning Products...
Page 10
FTP Server For Sales or Corporate Information Tell Us What You Think...
Page 11
Table 1 AT-9006 Gigabit Ethernet Switch Models Number of Type of Model Type of Port Maximum Distance Ports Connector AT-9006SX/SC 1000Base-SX 550 m (1,804 ft) 220 m (722 ft) AT-9006LX/SC 1000Base-LX 10,000 m (32,800 ft) 1. Both models include two expansion slots.
ACTIVITY DO NOT STARE INTO BEAM FULL DUP HALF DUP FAULT L /A L /A L /A RESET Figure 1 AT-9006SX/SC Front Panel AT-9006LX/SC 1000BASE-SX GIGABIT ETHERNET SWITCH 1000BASE-SX PORT ACTIVITY RS-232 STATUS TERMINAL PORT L /A L /A L /A...
Page 14
Installing the Switch On a Desktop AT-A15/SX, AT-A15/LX, AT-A16, AT-A17, AT-A18, and AT-A19 Quick Install Guide...
Page 15
AT-9006 Quick Install Guide RPS Power Connecto AC Power Connector Figure 3 Switch Rear Panel RS-232 STATUS TERMINAL PORT Fault LED FAULT RESET Figure 4 Fault LED...
Page 16
Installing the Switch in a Rack AT-A15/SX, AT-A15/LX, AT-A16, AT-A17, AT-A18, and AT-A19 Quick Install Guide Figure 5 Removing the Feet O R T R S - T E R 2 3 2 M I N A L P O R T S T A T F A U R E S...
Solid Green This indicates a link. Flashing Green This indicates activity. Duplex/Collision Solid Green The port is operating at full-duplex. Solid Amber The port is operating at half-duplex. Flashing Amber Collisions are occuring on the line. AT-9006SX/SC and AT-9006LX/SC Installation Guide...
Page 20
AT-S26 Software Default Setting Table 4 Ethernet Switch Default Settings Settings Default IP Address 0.0.0.0 Subnet Mask 0.0.0.0 Gateway Address 0.0.0.0 Get Community String public Set Community String private Trap Community String public Spanning Tree Protocol Disabled Bridge Priority 32768 Bridge Max Age Time Bridge Hello Time Bridge Forwarding Delay...
AT-9006 Quick Install Guide R.P.S. Input Connector Specifications Table 5 RPS Input Port Pin Assignments Pin Number Function +12V dc Remote Sense (RS) +5V dc Remote Sense (RS) Ground Remote Sense (RS) +3.3V dc Redundant Power Supply (RPS) Present Ground (+3.3V dc Return) Ground (+5V dc Return) +5V dc Ground (+12V dc Return)
Technical Specifications AT-9006 Ethernet Switch Installation Guide Table 6 Technical Specifications Physical Specifications 6.48 cm x 42.93 cm x 35.60 cm Dimensions (H x W x D) (2.55 in x 16.9 in x 14.0 in) 6.12 kg (13.60 lbs) Weight Required Ventilation (all sides) 19 cm (7.5 in) Environmental Specifications...