Digital Blood Pressure Monitor Model UA-705 Instruction Manual Original Manuel d’instructions Traduction Manual de Instrucciones Traducción Manuale di Istruzioni Traduzione 使用手冊 翻譯 1WMPD4000988D...
Congratulations on purchasing a state-of-the-art A&D blood pressure monitor, one of the most advanced monitors available today. Designed for ease of use and accuracy, this device will facilitate your daily blood pressure regimen. We recommend that you read through this manual carefully before using the device for the first time.
Precision components are used in the construction of this device. Extremes in temperature, humidity, direct sunlight, shock or dust should be avoided. Clean the device and cuff with a dry, soft cloth or a cloth dampened with water and a neutral detergent. Never use alcohol, benzene, thinner or other harsh chemicals to clean the device or cuff.
Parts Identification Display Air socket Air connector plug Start button Exhaust valve Air hose Ruber bulb Artery position mark Proper fit range Index mark Arm cuff Battery cover Battery compartment Battery LR6P, R6 or AA Part Of Display Heart mark Systolic pressure MEMORY Diastolic pressure...
Symbols Function / Meaning Recommended Action Standby and ON switch. Battery installation guide Type BF: Device, cuff and tubing are designed to provide special protection against electrical shocks. The indicator that appears while Measurement is in progress. measurement is in progress. It blinks Remain as still as possible.
(LOW BATTERY mark) does not appear when the battery is drained. Battery life varies with the ambient temperature and may be shorter at low temperatures. Use the specified battery only. The battery provided with the device is for testing monitor performance and may have a limited life.
The arm size is printed on each cuff. The index and proper fit range, on the cuff, tell you if you are applying the correct cuff. (Refer to "Applying The Arm Cuff" on next page) If the index points outside of the range, contact your local dealer to purchase a replacement cuff.
Clearing data : Remove the battery and re-install it....................... After Measurement After the measurement is completed, remove the cuff and record your data, then press the button to turn off the power. START Note: The device is an automatic power shut-off function, which turns the power off approximately one minute after measurement.
2. Press the button. START The buzzer sounds and the average blood pressures and the WHO classification and last data number are displayed briefly. When the " 0 " is flashing, the device is ready for measurement. If the mark is displayed, the cuff has some air trapped in it.
Your blood pressure varies constantly, depending on what you are doing and what you have eaten. What you drink can have a very strong and rapid effect on your blood pressure. This device bases its measurements on the heartbeat. If you have a very weak or irregular heartbeat, the device may have difficulty determining your blood pressure.
An irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all heartbeats during the blood pressure measurement. It is important that you are relaxed, remain still and do not talk during measurements.
Regular readings give a more comprehensive blood pressure history. Be sure to note date and time when recording your blood pressure. Consult your doctor to interpret your blood pressure data.
Maintenance Do not open the device. It uses delicate electrical components and an intricate air unit that could be damaged. If you cannot fix the problem using the troubleshooting instructions, request service from your dealer or from the A&D service group. The A&D service group will provide technical information, spare parts and units to...