Electrical feeder cable connection
To connect the supply cable:
- Remove the screws securing the cover "A" on the rear of the cooker (fig. 44).
- Feed the supply cable through the cable clamp "D". The supply cable must be of a
suitable size for the current requirements of the appliance; see the section "Feeder cable
section".
- Connect the wires to the terminal block "B" as shown in the diagram in figure 45; or
connect the phase wires to the terminal block "B" and the earth wire to the terminal PE
as shown in figure 44.
- Take up any slack in the cable and secure with the cable clamp "D".
- Replace the cover "A".
Before carrying out any work on the electrical parts of the appliance, the appliance
must first be disconnected from the electrical supply.
Feeder cable section type H05RR-F
230 V
3 x 2,5 mm
(**) – Connection with wall box connection.
Earth cable must be 2 cm longer than neutral and live cables.
B
A
Fig. 44
44
2
(**)
PE
N
L
D
230 V
L
N
PE
1
(L
)
2
Fig. 45